Check
SiENBE04-401A
142
Service Diagnosis
5.1.6 Outdoor Unit Fan System Check
Check No.9
DC motor — (A)RK(X)S models
AC motor — (A)RK(X)H, R(Y)N models
Check the outdoor unit fan system.
Reconnect.
(R2857)
Outdoor unit fan running?
YES
Fan motor lead wire
connector disconnected?
YES
NO
NO
Outdoor unit fan system
functioning.
Go to
Check No. 15
.
Check the
fan motor lead wire
connector for secure
connection.
Abnormal
YES
NO
NO
Continuity
Are the
resistance at connector
leads
∞
? 1. red - black,
2. white - black
Check the fan
capacitor for continuity.
Does the outdoor
fan rotate?
Does
the outdoor unit fan
start just after the power
is turned on?
Check the outdoor fan system.
YES
YES
NO
Normal
No continuity
Repair.
Replace the fan motor.
Replace the fan motor.
Replace the outdoor unit PCB.
The outdoor fan system is
normal.
(R2670)
Содержание ARKH20CAVMB
Страница 19: ...List of Functions SiENBE04 401A 10 List of Functions ...
Страница 20: ...SiENBE04 401A Specifications 11 Part 2 Specifications 1 Specifications 12 1 1 Cooling Only 12 1 2 Heat Pump 20 ...
Страница 45: ...Specifications SiENBE04 401A 36 Specifications ...
Страница 81: ...Control Specification SiENBE04 401A 72 Function and Control ...
Страница 111: ...Instruction SiENBE04 401A 102 System Configuration ...
Страница 155: ...Check SiENBE04 401A 146 Service Diagnosis ...
Страница 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 401A 216 Removal Procedure ...
Страница 226: ...SiENBE04 401A Others 217 Part 8 Others 1 Others 218 1 1 Test Run from the Remote Control 218 1 2 Jumper Settings 219 ...
Страница 229: ...Others SiENBE04 401A 220 Others ...
Страница 239: ...Wiring Diagrams SiENBE04 401A 230 Appendix ...