WIRING DIAGRAMS
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
60
0140G04507-B
INSTALLER/SERVICEMAN
-
GAS
PR
ESS
UR
E
FLA
ME
R
OLL
OU
T
AU
X. LIMIT OPEN
FLA
ME
S
EN
SO
R
BA
D SWIT
CH
GAS VALVE
CHECK
FUSE ON C
ON
TROL
CHECK INPU
T POWER
RE
PL
ACE
CO
NT
RO
L
GAS FLOW
ANTI
-CYCL
E TI
ME
R
MAIN LIMI
T OPEN
ST
IC
KI
NG G
AS
V
AL
VE
BA
D SWIT
CH
3 MIN.
C
OMP.
PR
ES
SUR
E SWIT
CH
PR
ES
SUR
E SWIT
CH
CH
EC
K
CH
EC
K
OF
F
ON
OR
OR
1 BLINK
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
FALSE FLA
ME SE
N
SED
OUTP
UT
D
ELAY
OPEN LIMI
T SWIT
CH
CO
MP
R
ESSOR
WIT
HO
UT
INDUCE
R
ON
PRES
SURE SWI
TC
H
CLOSED
PR
ES
SURE
SWI
TC
H
OPEN
A
UX
. LIMIT
OPEN
R
OLLO
UT
SWIT
CH
OPEN
SWIT
CH
IGNI
TION
FAILU
RE
NORM
AL
OP
ER
ATION
NO
P
OW
ER
O
R
INTE
RN
AL
CO
NTRO
L
FAU
LT
ST
AT
U
S LIG
HT
EQUI
P. STATU
S
CH
EC
K
TR
OU
BLESH
OO
TI
NG
THIS
APPLIANCE.
ST
AT
US
LI
GHT C
OD
ES A
RE AS
F
OLLOWS
:
THE
ST
AT
US
LIG
HT
O
N TH
E FU
RNA
CE
C
ONT
RO
L
MAY BE U
SED
AS
A G
UIDE
TO
RD
PU
BK
BR
PU
BK
CM
CO
NNEC
TED
AT
L1, L
2
BK
BK
NO
TE
3
CH
OPTIO
NAL
RS
CO
MP
C
RD
RD
BL
WH
RD
PU
OR
RD
BL
YL
HC
F
RD
WH
WH
YL
YL
SE
E
NO
TE
7
YL
WH
BL
BL
BL
BR
BR
RD
OR
BL
BL
BL
BL
RD
RD
RD
RD
PU
WH
OR
RD
YL
YL
Y/Y
2
IGN
FS
RC
CF
PU
BL
BR
PU
RD
RD
YL
YL
RS
PU
PU
BL
VM
PU
L2
UNUSED
HEAT
FS
L1
DI
1
3
6
5
2
4
10
7
9
12
8
11
15
0
12
0
ECON
13
5
P1
F1
FUSE 3 AMP
M
AX
P3
GR
RD
YL
WH
YL
YL
COMPRESSOR
COOL
SCREW
REQUIRED
P2
T1
MOUNT
C2
2
T2
BREAK FOR TWO STAGE
SPEED-UP
GR
WH
WH
GR
BL
RD
C
RD
TO
THE
RM
OSTAT
ALS
PS
GV
MV
(AL
T.)
HO
NEY
WELL
GAS
V
AL
VE
GV
MV
GAS
V
AL
VE
W. R
.
RS
II
C
HPS
YL
LS
L1
L2
CC
T1
T2
BL
RD
BL
BK
PU
BK
YL
RD
GN
D
POWER SUPPLY 208-230/1/60
CH
O
PTIO
NAL
SE
E NOTE 3
BK
BK
1 C
24V
BL
RD
2
TR
3 240
3
4
2
1
RD
VM
R
BK
PU
PU
BL
PU
YL
208
NO
TE 2
SE
E NOTE 5
RD
YL
BK
BK
OPTIO
NAL LOW VOL
TAG
E
OPTIO
NAL HI
GH
VOLTAG
E
FIELD I
NSTALLED
CO
NT
ROL
FIELD I
NSTALLED POWE
R
NO
TES
:
1. REPLACEM
ENT
W
IRE MUST BE THE SAM
E SIZE AND
TY
PE
O
F
INSU
LATION AS
ORIGINAL.(U
SE C
OPPER
CO
NDUCTOR
ONLY
).
2. FOR 208 VOLT TRANSFORM
ER OPERA
TI
ON MOV
E
BLACK
WI
RE
FR
OM
TER
MI
NAL 3 TO TER
MI
NA
L 2 O
N
TRANSFOR
MER.
3. CRAN
KCASE
HE
AT
ER
NOT SUPPLIE
D
ON ALL UN
IT
S.
4. FOR D
IF
FE
RENT TH
AN FACTORY
SPEED TAP. CHAN
GE COOLING
SPEED AT
M
OT
OR T
4 AND
T
5
TE
RM
INALS. CHAN
GE HEATIN
G
SPEED AT
M
OT
OR T
1, T
2 AND
T3
TER
MI
NA
LS
.
CO
O
LI
NG
S
PE
ED
(Y
EL
LO
W
W
IRE)
H
EA
TI
NG
S
PE
ED
(WH
IT
E
W
IRE)
T
4 - LOW
SPE
ED
T1
- LOW
SPEED
T
5 -
HI
GH SPEED
T2 -
M
ED. SPEED
T3 - HIGH SPEED 5. USE CO
OPER CONDUC
TO
RS ONL
Y
CO
MPO
NE
NT LEGEND
ALS
A
UX
ILLARY L
IM
IT SWI
TCH
CO
MP
C
OM
PRESSOR
CM
CON
DENSER
M
OTOR
C CO
N
TAC
TO
R
CH
C
RANKCASE HEATER
EM EVA
PORAT
OR
M
OTOR
F
F
USE
FS
F
LA
ME SENSO
R
GN
D EQUI
PM
EN
T
GR
OU
ND
GV GAS
V
AL
VE
HPS HIGH PRESSURE SWIT
CH
IIC IN
TEGRA
TED IG
NI
TI
ON
C
ON
TRO
L
IGN I
GN
IT
OR
LS LIM
IT
SWI
TC
H
PS
PRES
SURE SWIT
CH
RC
C
F
RU
N CAPACI
TO
R
FO
R
CO
MP
RESSOR/FAN
RS ROLL
OU
T SW
IT
CH
TR
TRANS
FO
RM
ER
VM VENT
M
OTOR
VM
R VENT
M
OTOR
R
ELAY
PU - PU
RPLE
YL
- Y
ELLOW
WH
-
WH
IT
E
RD
-
RED
BL - BLU
E
BR - B
RO
WN
GR
-
GREEN
OR
- ORANG
E
PK - PINK
WIRE C
ODE
BK - BLACK
LOW VOL
TAG
E
WIRI
NG
HIG
H VOLTAG
E
USE NEC CLASS 2
W
IRE.
208-
23
0/
1/60
BL
YL
RD
GR
WH
NO ECO
NO
M
IZER
W
Y
C
R
G
THE
RM
OSTAT
F
IELD
W
IRI
NG
BL/
PK
- BLUE/PINK
YL
BL
24 V
H
C
EM
RG
W
TO THERMOSTA
T
11
Y/Y
2
C
4
9
7
8
10
12
6
5
3
FS
F
L1
PS
AL
S
RS
LS
GV
FS
IGN
VM
L2
SUPPLY VOLTAGE
1
C
CO
MP
S
C
T1
R
L1
C
CM
208-230/1/60
T2
CH
2
L2
NO
TE 3
TR
C
D1
C
13
EM
VMR
VM
R
2
T4
T3
L
N
3
2
1
IIC
T5
2T1
T
C
RC
CF
F
H
NO
TE 2
4
HPS
NO
TE 4
C
T1
T2
T3
T4
T5
LG
N
EM
WH Y
L
GR
PU
BL
BK
YL
YL
2
A/GPGM3[48]***M41**