BLOWER PERFORMANCE DATA
48
CFM Output
for DIP Switches 1 -2 / Heating
CFM Output
for DIP Switches 5 - 6 / Cooling
MODEL
SPEED
TAP
Switch
1
Switch
2
Low
Heat
CFM
High
Heat
CFM
Switch
5
Switch
6
Low
Cool
CFM
High Cool
CFM
APGM52406041**
A
OFF
OFF
600
800
OFF
OFF
565
750
B
ON
OFF
675
900
ON
OFF
600
800
C
OFF
ON
735
980
OFF
ON
620
825
D
ON
ON
X
X
ON
ON
640
850
APGM53008041**
A
OFF
OFF
800
1065
OFF
OFF
605
900
B
ON
OFF
900
1195
ON
OFF
670
1000
C
OFF
ON
1000
1330
OFF
ON
720
1075
D
ON
ON
X
X
ON
ON
735
1100
APGM53608041**
A
OFF
OFF
800
1065
OFF
OFF
755
1125
B
ON
OFF
900
1195
ON
OFF
805
1200
C
OFF
ON
1000
1330
OFF
ON
840
1250
D
ON
ON
X
X
ON
ON
890
1325
APGM54210041**
A
OFF
OFF
1015
1350
OFF
OFF
1080
1300
B
ON
OFF
1125
1495
ON
OFF
1160
1400
C
OFF
ON
1250
1665
OFF
ON
1205
1450
D
ON
ON
X
X
ON
ON
1245
1500
APGM54810041**
A
OFF
OFF
1015
1350
OFF
OFF
1275
1450
B
ON
OFF
1125
1495
ON
OFF
1320
1500
C
OFF
ON
1250
1665
OFF
ON
1365
1550
D
ON
ON
X
X
ON
ON
1410
1600
MODEL
SWITCH
3
SWITCH
4
THERMOSTAT
APGM5**
N/A
ON
Single Stage
N/A
OFF
Two-Stage
CFM
SWITCH
7
SWITCH
8
+10%
ON
OFF
Normal
OFF
OFF
-10%
OFF
ON
x = Not recommended for heating application
DIP Switch Settings
for Single and Two-Stage Thermostats
Adjustments Through Dip Switch
Combinations 7-8
APGM5** CFM OUTPUT AND DIP SWITCH SETTINGS