8 Configuration
Installer reference guide
49
EPGA11~ EA9W
Daikin Altherma – Low temperature split
4P556075-1 – 2019.02
#
Code
Description
[3.8.2]
[9-06]
Heating maximum
▪ [2‑0D]=2 (emitter type additional zone
= radiator)
37°C~60°C
▪ Else: 37°C~55°C
[3.8.3]
[9-07]
Cooling minimum: 5°C~18°C
[3.8.4]
[9-08]
Cooling maximum: 8°C~22°C
Control
The control type is displayed here, but cannot be adjusted. It is
determined by the control type of the main zone. For more info about
the functionality, see
#
Code
Description
[3.9]
N/A
Control
▪ Leaving water if the control type of the
main zone is Leaving water.
▪ External room thermostat if the control
type of the main zone is External room
thermostat or Room thermostat.
Thermostat type
Only applicable in external room thermostat control. For more info
about the functionality, see
#
Code
Description
[3.A]
[C‑06]
External room thermostat type for the
additional zone:
▪ 1: 1 contact. Connected to only 1
digital input (X2M/35a)
▪ 2: 2 contacts. Connected to 2 digital
inputs (X2M/34a and X2M/35a)
Leaving water temperature: Delta T
#
Code
Description
[3.B.1]
[1-0C]
Delta T heating: A minimum temperature
difference is required for the good
operation of heat emitters in heating
mode.
▪ If [2-0D] = 2, this is fixed to 8°C
▪ Else: 3°C~10°C
[3.B.2]
[1-0E]
Delta T cooling: A minimum temperature
difference is required for the good
operation of heat emitters in cooling
mode.
▪ 3°C~10°C
8.4.5
Space heating/cooling
Cooling settings are only applicable in case a conversion
kit (EKHVCONV2) is installed.
About space operation modes
Depending on your heat pump model, you have to tell the system
which space operation mode to use: heating or cooling.
If a … heat pump
model is installed
Then…
Heating/cooling
The system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.
If a … heat pump
model is installed
Then…
Heating only
The system can heat up a space, but
NOT cool down a space. You do NOT
have to tell the system which space
operation mode to use.
To determine if a heating/cooling heat pump model is installed
1
Go to [4]: Space heating/cooling.
2
Check if [4.1] Operation mode is listed and editable.
If so, a heating/cooling heat pump model is installed.
To tell the system which space operation to use, you can:
You can…
Location
Check
which space operation mode is
currently used
.
Home screen
Set
the space operation
mode
permanently. Main menu
Restrict
automatic changeover
according
to a monthly schedule.
To check which space operation mode is currently used
The space operation mode is displayed on the home screen:
▪ When the unit is in heating mode, the
icon is shown.
▪ When the unit is in cooling mode, the
icon is shown.
The status indicator shows if the unit is currently in operation:
▪ When the unit is not in operation, the status indicator will show a
blue pulsation with an interval of approximately 5 seconds.
▪ While the unit is in operation, the status indicator will light up blue
constantly.
To set the space operation mode
1
Go to [4.1]: Space heating/cooling > Operation mode
2
Select one of the following options:
▪ Heating: Always heating mode
▪ Cooling: Always cooling mode
▪ Automatic:
The
operation
mode
changes
automatically based on the outdoor temperature.
Restricted according to the operation mode
schedule.
Automatic heating/cooling changeover is only applicable for EABX,
EAVX and EAVZ (only with EKHVCONV2 installed).
When Automatic is selected, the changing of the operation mode is
based on the Operation mode schedule [4.2]: the end user indicates
on a monthly base which operation is allowed.
Operation range
Depending on the average outdoor temperature, the operation of the
unit in space heating or space cooling is prohibited.
#
Code
Description
[4.3.1]
[4-02]
Space heating off temperature: When the
averaged outdoor temperature rises
above this value, space heating is turned
off. This setting is also used in automatic
heating/cooling changeover.
▪ 14°C~35°C
[4.3.2]
[F-01]
Space cooling off temperature: When the
averaged outdoor temperature drops
below this value, space cooling is turned
off. This setting is also used in automatic
heating/cooling changeover.
▪ 10°C~35°C