7 Installation
Installer reference guide
32
EPGA11~ EA9W
Daikin Altherma – Low temperature split
4P556075-1 – 2019.02
2
Strip insulation (20 mm) from the wires.
a
b
a
Strip wire end to this point
b
Excessive strip length may cause electrical shock or
leakage.
3
Insert the wiring at the back of the unit:
b
c
a
a
Power supply cable (high voltage)
b
Communication cable (high voltage)
c
Cable for bottom plate heater (optional)
4
Inside the unit, route the wiring as follows:
b
f
a
e
e
d
c
e
e
e
a
Power supply cable
b
Communication cable
c
Cable for bottom plate heater (optional)
d
Ferrite core
e
Tie strap
f
Compressor
NOTICE
To guarantee electromagnetic compatibility:
▪ Make sure both power supply and communication
cables run parallel to one another. Use tie straps to
hold the cables together.
▪ Make sure the cables are located as far away from the
compressor as possible.
▪ The communication cable MUST pass through the
ferrite core.
5
Make sure that the cable does NOT come in contact with sharp
edges or hot gas piping.
6
Install the switch box cover.
INFORMATION
When installing field supply or option cables, foresee
sufficient cable length. This will make it possible to remove/
reposition the switch box and gain access to other
components during service.
CAUTION
Do NOT push or place redundant cable length in the unit.
7.6.7
To connect the electrical wiring on the
indoor unit
1
To open the indoor unit, see
"7.2.3 To open the indoor unit" on
and
"7.2.4 To open the switch box cover of the indoor
.
2
The wiring enters the unit from the top:
b+c
a
d
a, b, c
Field wiring (see table below)
d
Factory-mounted cable for power supply of backup heater
3
Routing of the wiring inside the unit should be as follows. Fix
the cable to the cable rail using cable ties:
a
4×
b+c
Routing
Possible cables (depending on unit type
and installed options)
a
Low voltage
▪ Preferential power supply contact
▪ User interface (option)
▪ Power consumption digital inputs (field
supply)
▪ Outdoor ambient temperature sensor
(option)
▪ Indoor
ambient
temperature
sensor
(option)
▪ Electrical meters (field supply)
▪ Safety thermostat (field supply)
b
High voltage power
supply
▪ Interconnection cable
▪ Normal kWh rate power supply
▪ Preferential kWh rate power supply