10
|
Configuration
Installer reference guide
133
E EHFH03S18D
Daikin Altherma 3 R F
4P596806-1C – 2022.09
#
Code
Description
[A.4.5]
[6-0E]
The maximum temperature that users can select
for the domestic hot water. You can use this
setting to limit the temperature at the hot water
taps.
INFORMATION
There is a risk of space heating (or cooling) capacity shortage/comfort problem when
selecting [6‑0D]=0 ([A.4.1] Domestic hot water
Type
=
Reheat only
).
In case of frequent domestic hot water operation, frequent and long space heating
interruption will happen.
Maximum DHW temperature setpoint
The maximum temperature that users can select for the domestic hot water. You
can use this setting to limit the temperatures at the hot water taps.
INFORMATION
During disinfection of the domestic hot water tank, the DHW temperature can
exceed this maximum temperature.
INFORMATION
Limit the maximum hot water temperature according to the applicable legislation.
#
Code
Description
[A.4.5]
[6-0E]
Maximum setpoint
The maximum temperature that users can select
for the domestic hot water. You can use this
setting to limit the temperature at the hot water
taps.
The maximum temperature is NOT applicable
during disinfection function. See disinfection
function.
10.2.6 Contact/helpdesk number
#
Code
Description
[6.3.2]
N/A
Number that users can call in case of problems.
10.3 Weather-dependent curve
10.3.1 What is a weather-dependent curve?
Weather-dependent operation
The unit operates 'weather-dependent' if the desired leaving water or tank
temperature is determined automatically by the outdoor temperature. It therefore
is connected to a temperature sensor on the North wall of the building. If the
outdoor temperature drops or rises, the unit compensates instantly. Thus, the unit
does not have to wait for feedback by the thermostat to increase or decrease the