8 Technical data

Installation manual

26

EBLQ+07CAV3

Daikin Altherma low temperature monobloc

4P403578-1C – 2016.02

Control box option: option box

X1M/L

X1M/N

X1M/PE

A4P/X5A.1
A4P/X5A.2
A4P/X5A.3

F2U

X1A

X2A

1 2 3

X5A

X1M

1 2 3 4 5

X8M

X2M

3

2

1

5
4

3

2

1

1 2 3 4 5 6 7 8

X3A

X4A

X2M

1 2 3 4 5 6

X14A

ON

OFF

8  7  6  5  4  3  2  1

DS1

F1U

1 2 3

14

5 6 3 4 1 2 1a 2a

7 8 9 10 11 12

15

13

A4P

L N

+12V

GND

S1P

S2P

S3P

R6T

-t°

S5P

S6P

S4P

1 2

4D094176-1C_Page 10

Control box

Option box

Power limitation digital inputs:

5 V DC detection

(voltage supplied by PCB)

Power limitation

digital input :

5 V DC detection

(voltage supplied by PCB)

external indoor ambient

sensor option 

Electric pulse meter inputs:

5 V DC pulse detection

(voltage supplied by PCB)

Alarm output

Max. load 150mA - 12 V DC

Space C/H ON/OFF output

Max. voltage 250V AC

Max. load 1A

Min. load 10mA

Ext. heat sourc

Max. voltage 250V AC

Max. load 1A

Min. load 10mAe

A1P

Main PCB

A2P

Current loop PCB

A3P

*

On/OFF thermostat (PC=power circuit)

A3P

*

Heat pump convector

A4P

*

Extension PCB (control, optional)

A5P

User interface PCB

A7P

*

Receiver PCB (wireless On/OFF thermostat)

B1L

Flow sensor

C110~C112

Capacitor

DB1, DB2, DB401

Rectifier bridge

DS1 (A4P)

*

DIP switch

E1H

Backup heater element (1 kW)

E2H

Backup heater element (2 kW)

E3H

Backup heater element

E4H

Booster heater (3 kW)

E6H

Plate heat exchanger heater tape

E7H

Expansion vessel heater

F1B

*

Overcurrent fuse backup heater

F2B

*

Overcurrent fuse booster heater

F1T, F2T

*

Thermal fuse backup heater

F1U (A4P)

Fuse T 2 A 250 V

F2U (A4P)

Fuse T 2 A 250 V for 3‑way valve

FU1 (A1P)

Fuse T 6.3 A 250 V

FU2 (A1P)

Fuse T 6.3 A 250 V

K1

*

Terminal strip

K2

*

Booster heater

FU1, FU3 (PCB1)

Fuse

FU2 (PCB2)

Fuse

IPM1

Intelligent power module

K1A

Relay for heating

K2A

Relay for cooling

K1M

*

Contactor backup heater (step 1)

K2M

*

Contactor backup heater (step 2)

K3M

*

Contactor booster heater

K5M

*

Safety contactor backup heater (only for
*9W)

K1R

*

Backup heater relay (step 1)

K2R

*

Backup heater relay (step 2)

K*R

Relay on PCB

LED 1~LED 4

Indication lamp

LED A, LED B

Pilot lamp

M1C

Compressor motor

M1F

Fan motor

M1P

Main supply pump

Содержание Altherma EDLQ05CAV3

Страница 1: ...Installation manual Daikin Altherma low temperature monobloc English Installation manual Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3...

Страница 2: ...mi pokyny odpov daj n sleduj c m norm m nebo normativn m dokument m u skladu sa slijede im standardom ima ili drugim normativnim dokumentom ima uz uvjet da se oni koriste u skladu s na im uputama 16 1...

Страница 3: ...ture Overview installer settings 17 6 Commissioning 18 6 1 Checklist before commissioning 18 6 2 Checklist during commissioning 18 6 2 1 To perform an air purge 18 6 2 2 To perform a test run 19 6 2 3...

Страница 4: ...o check the water volume and flow rate Minimum water volume If Then The system contains a backup heater The minimum water volume is 10 l a The system does NOT contain a backup heater The minimum water...

Страница 5: ...75 mm d Cable section 0 75 mm till 1 25 mm maximum length 20 m e If valve kit EKMBHBP1 is part of the system then the required cable section is 0 75 mm If valve kit EKMBHBP1 is NOT part of the system...

Страница 6: ...e unit Additionally make sure the unit is positioned at least 100 mm above the maximum expected level of snow mm 1 5 0 1 5 0 a 330 300 283 7 4 0 0 mm 100 a Maximum snowfall height It is possible to in...

Страница 7: ...condensate may also form in the hydro part When providing drainage therefore make sure to cover the entire unit NOTICE If the unit is installed in a cold climate take adequate measures so that the eva...

Страница 8: ...e piping from freezing Protection against freezing the glycol will prevent the liquid inside the piping from freezing Lowest expected outdoor temperature Prevent from bursting Prevent from freezing 5...

Страница 9: ...ter circuit For instructions see 6 Commissioning on page 18 6 Refill the circuit until the pressure is 2 0 bar 7 Repeat steps 5 and 6 until no more air is purged and there are no more pressure drops 8...

Страница 10: ...power supply 1 Connect the main power supply 1 2 3 X4M 2 3 1 1 GND 2 L 3 N 4 4 3 To connect the user interface INFORMATION If control box EKCB07CAV3 is NOT part of the system connect the user interfa...

Страница 11: ...ted to the outdoor unit However if control box EKCB07CAV3 is present in the system you can also connect it to the control box To do this connect outdoor unit terminals X3M 1 2 to control box terminals...

Страница 12: ...r more than 1 hour or press again for more than 4 seconds the installer permission level switches back to End user To set the user permission level to Advanced end user 1 Go to the main menu or any of...

Страница 13: ...See also illustrations below Domestic hot water pump installed for Instant hot water Disinfection c f a g h b c h b a d f e g a Outdoor unit b Tank c Domestic hot water pump d Heater element e Non ret...

Страница 14: ...nction between the detection of an alarm and the detection of a power failure See also table below Alarm output logic A 2 2 F 3 D 08 Optional external kWh meter 1 0 No NOT installed 1 Installed 0 1 pu...

Страница 15: ...g water In case a minimum temperature difference is required for the good operation of the heat emitters in heating mode A 3 1 3 2 9 0A Cooling required temperature difference between entering and lea...

Страница 16: ...cool down cycle 5 2 6 Domestic hot water control Code Description A 4 1 6 0D Domestic hot water Type 0 Reheat only Only reheat operation is allowed 1 Reheat sched Same as 2 but between the scheduled h...

Страница 17: ...ones Pump operation mode Power saving possible User interface location Options DHW pump External sensor Control box Option box Leaving water Main Additional Delta T source Room thermostat Room temp ra...

Страница 18: ...r heater Booster heater circuit breaker F2B on the switch box of the control box is turned ON The correct pipe size is installed and the pipes are properly insulated There are no water leaks inside th...

Страница 19: ...eaving water temperature home page room temperature home page and domestic hot water home page are turned OFF 1 Set the user permission level to Installer See To set the user permission level to Insta...

Страница 20: ...lation to maintaining the unit Explain the user about energy saving tips as described in the operation manual 7 1 About locking and unlocking If required it is possible to lock the buttons of the main...

Страница 21: ...door unit See the internal wiring diagram supplied with the unit on the inside of the outdoor unit switch box cover The abbreviations used are listed below Position in switch box hydro switch box A1P...

Страница 22: ...M L PCB3 PCB2 PCB1 GRN GRN GRN RED RED RED RED 1 S502 2 3 4 5 6 7 8 9 10 11 S503 1 2 3 4 5 S501 1 2 3 4 5 SW5 SW2 SW1 SW3 A 1 2 3 4 DB1 DB2 HL402 HN402 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 1 2 3 4 5 6 7...

Страница 23: ...L1 HN1 30A V3 S10 3 2 1 MR30_A MR30_B 1 2 S20 S50 1 2 3 4 5 1 2 3 4 DP2 DP1 MR307 MR306 FU1 T3 15A V401 DB401 1 2 3 4 5 6 1 2 3 4 1 2 3 4 5 6 7 WHT YLW ORG BLU RED Y1E M S1NPH S60 S90 S40 R3T t R2T t...

Страница 24: ...A X7A X21A K4R K6R X10A X14A X15A X18A 1 2 3 4 5 3 1 1 3 1 2 A1P TR1 M1P S1L N L GND PWM PE MS 3 t t t R3T R4T R1T X10A X1A X5M X3M X5Y A2P 4 3 4 3 2 1 2 1 X2M 23 X2M 22 X2M 21 X2M 20 X8M 9 X8M 8 X8M...

Страница 25: ...onvector only for wireless On OFF thermostat 4D094176 1C_Page 8 User interface Remote user interface Option box DHW pump output Max load 2 A inrush 230 V AC 1 A continuous DHW pump Dual setpoint appli...

Страница 26: ...PCB A3P On OFF thermostat PC power circuit A3P Heat pump convector A4P Extension PCB control optional A5P User interface PCB A7P Receiver PCB wireless On OFF thermostat B1L Flow sensor C110 C112 Capac...

Страница 27: ...mistor air R1H A3P Humidity sensor R4T A1P Inlet water thermistor R5T Domestic hot water thermistor R6T A1P External outdoor ambient thermistor R6T A4P External indoor ambient thermistor S1L Flow swit...

Страница 28: ...a 2 Only for heat pump convector Only for KRTR wireless room thermostat Only for KRTW wired room thermostat 2 core 3m included signal R2T External sensor floor or ambient Only for KRTETS External indo...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...4P403578 1C 2016 02 Copyright 2015 Daikin...

Отзывы: