7 Installation
Installer reference guide
36
EBLQ+EDLQ011~0W1 + EK(2)CB07CAV3
Daikin Altherma low temperature monobloc
4P538847-1 – 2018.05
b
a
W1
a
Power supply cable
b
Cable tie
5
Make sure that the cable does NOT come in contact with sharp
edges or hot gas piping.
6
Install the switch box cover.
INFORMATION
When installing field supply or option cables, foresee
sufficient cable length. This will make it possible to remove/
reposition the switch box and gain access to other
components during service.
CAUTION
Do NOT push or place redundant cable length in the unit.
7.7.5
To connect the main power supply
1
Connect the main power supply as follows:
X1M
1 2 3 L N
a
b
V3
1 2 3 L1 L2 L3 N
X1M
a
W1
a
Power supply cable (including earth)
b
Cable tie
2
Open the switch box and route the wiring as follows.
In case of normal kWh rate power supply
X5M
A2P
X6Y
X1A
X4M
X3M
X6YA
X19A
In case of preferential kWh rate power supply
1 2
9
10
X5M
A2P
X6Y
X1A
X6YB
X4M
X3M
5
6
X6YA
X19A
X2M
X8M
S1S
b
a
a
Normal kWh rate power supply
b
Preferential power supply contact (on the control box)
INFORMATION
For the exact position of connectors X6Y, X6YA, and X6YB
in the switch box, see the service manual.