8.3 Symptom: You are feeling too cold (hot) in your living room
Possible cause
Corrective action
The desired room temperature is too
low (high).
Increase (decrease) the desired room
temperature. See
If the problem recurs daily, do one of
the following:
▪
Increase
(decrease)
the
room
temperature
preset
value.
See
▪
Adjust
the
room
temperature
schedule. See
35] and
38].
The desired room temperature cannot
be reached.
Increase the desired leaving water
temperature in accordance with the
heat emitter type. See
the desired leaving water
temperature"
29].
The weather-dependent curve is set
incorrectly.
Adjust the weather-dependent curve.
See
44].
8.4 Symptom: The water at the tap is too cold
Possible cause
Corrective action
You ran out of domestic hot water
because of unusual high consumption.
If you immediately need domestic hot
water, activate the DHW tank
Powerful operation
. However, this
consumes extra energy. See
"5.7.6 Using DHW powerful
operation"
33].
If the problems recurs daily, do one of
the following:
▪
Increase the DHW tank temperature
preset value. See
▪
Adjust the DHW tank temperature
schedule.
Example:
Program to
additionally heat up the DHW tank to
a preset value (
Eco setpoint
=
lower tank temperature) during the
day.
See
35] and
38].
The desired DHW tank temperature is
too low.