14 Technical data

Installer reference guide

88

EPGA11~ EAVH/9W

Daikin Altherma – Low temperature split

4P556070-1 – 2019.02

TC (A2P)

Signal transmission circuit

V1D~V4D (A1P)

Diode

V1R (A1P)

IGBT power module

V2R (A1P)

Diode module

V1T~V3T (A1P)

Insulated Gate Bipolar Transistor (IGBT)

X1M

Terminal strip

Y1E

Electronic expansion valve (main)

Y3E

Electronic expansion valve (injection)

Y1S

Solenoid valve (4‑way valve)

Y2S

Solenoid valve (hot gas bypass)

Y3S

Solenoid valve (injection bypass)

Z1C~Z11C

Noise filter (ferrite core)

Z1F~Z6F (A1P, A2P)

Noise filter

Содержание Altherma EAVX-D9WG

Страница 1: ...mperature split English Installer reference guide Daikin Altherma Low temperature split EPGA11DAV3 EPGA14DAV3 EPGA16DAV3 EAVH16S18DA6V G EAVH16S23DA6V G EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G...

Страница 2: ...ion vessel pre pressure 24 6 3 3 To check the water volume and flow rate 24 6 3 4 Changing the pre pressure of the expansion vessel 25 6 3 5 To check the water volume Examples 25 6 4 Preparing electri...

Страница 3: ...3 Symptom The compressor does NOT start space heating or domestic water heating 77 12 3 4 Symptom The system is making gurgling noises after commissioning 77 12 3 5 Symptom The pump is making noise ca...

Страница 4: ...T touch the air inlet or aluminium fins of the unit NOTICE Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit NOTICE Works executed on the outdoor unit are...

Страница 5: ...the cylinder is marked with Liquid filling siphon attached Charge with the cylinder upright A siphon tube is NOT present Charge with the cylinder upside down Open refrigerant cylinders slowly Charge...

Страница 6: ...terminal screws A screwdriver with a small head will damage the head and make proper tightening impossible Over tightening the terminal screws may break them Install power cables at least 1 metre away...

Страница 7: ...and service How to maintain and service the units Troubleshooting What to do in case of problems Disposal How to dispose of the system Technical data Specifications of the system Glossary Definition o...

Страница 8: ...sor leg in order to protect the unit during transport Proceed as shown in the figure and procedure below 1 Remove the nut a of the compressor mounting bolt 2 Remove and discard the transportation stay...

Страница 9: ...odel series 6V Backup heater model G G Grey model White model 4 3 Combining units and options 4 3 1 Possible options for the outdoor unit Bottom plate heater EKBPH140L7 Prevents freeze up of the botto...

Страница 10: ...ia a smartphone app Use the system in various Smart Grid applications For installation instructions see the installation manual of the LAN adapter LAN adapter for smartphone control BRP069A62 You can...

Страница 11: ...r interface For your daily needs you can use preset values and schedules To deviate from your daily needs you can temporarily overrule the preset values and schedules use the holiday mode Under floor...

Страница 12: ...condensation on the floor during cooling operation The desired room temperature is set via the remote controller of the heat pump convectors The space heating cooling demand signal is sent to one dig...

Страница 13: ...t the operation mode on each room thermostat must be set to match the indoor unit The room thermostats are connected to the shut off valves but do NOT have to be connected to the indoor unit The indoo...

Страница 14: ...re Number of water temperature zones 4 4 Code 7 02 0 Single zone Main 5 2 3 Multiple rooms Two LWT zones In this document Main zone Zone with the lowest design temperature in heating and the highest d...

Страница 15: ...an decrease or increase the desired leaving water temperature based on the actual room temperature modulation The combination of the two heat emitter systems provides the excellent heating comfort of...

Страница 16: ...em on page 10 The auxiliary contact can be An outdoor temperature thermostat An electricity tariff contact A manually operated contact Setup Connect the following field wiring L N H Com A K2A K1A X2M...

Страница 17: ...h day The lower the desired DHW tank temperature the more cost effective By selecting a larger DHW tank you can lower the desired DHW tank temperature The heat pump itself can produce domestic hot wat...

Страница 18: ...internally based on The leaving and entering water temperature The flow rate Setup and configuration No additional equipment needed 5 5 2 Consumed energy You can use the following methods to determine...

Страница 19: ...wer meter types Power meter 1 Single or three phase power meter according to the power supply of the outdoor unit Power meter 2 In case of a single phase backup heater configuration use a single phase...

Страница 20: ...Energy management system a Power limitation activation 4 digital inputs b Backup heater Pi t DI4 DI3 DI1 a b Pi Power input t Time DI Digital inputs power limitation levels a Power limitation active b...

Страница 21: ...sed in the weather dependent control curves and in the automatic heating cooling changeover logic To protect the outdoor unit the internal sensor of the outdoor unit is always used 6 Preparation 6 1 O...

Страница 22: ...igerant does NOT contain an odour WARNING The appliance shall be stored so as to prevent mechanical damage and in a well ventilated room without continuously operating ignition sources example open fl...

Страница 23: ...moisture dust If air moisture or dust gets into the circuit problems may occur To prevent this Only use clean pipes Hold the pipe end downwards when removing burrs Cover the pipe end when inserting i...

Страница 24: ...rdance with the applicable legislation it may be necessary to install thermostatic mixing valves Hygienic measures The installation must be in compliance with the applicable legislation and may requir...

Страница 25: ...NOT display error 7H NOTICE When circulation in each or certain space heating loops is controlled by remotely controlled valves it is important that the minimum flow rate is guaranteed even if all va...

Страница 26: ...he equipment is connected to such preferential kWh rate power supply the electricity company is allowed to interrupt power supply to the equipment for certain periods of time demand that the equipment...

Страница 27: ...4 GND 7 Installation 7 1 Overview Installation This chapter describes what you have to do and know on site to install the system Typical workflow Installation typically consists of the following stag...

Страница 28: ...h box 2 T25 7 2 4 To open the switch box cover of the indoor unit 4 T25 4 T25 7 2 5 To lower the switch box on the indoor unit During the installation you will need access to the inside of the indoor...

Страница 29: ...ion drawing Prepare 6 sets of anchor bolts nuts and washers field supply as follows 150 6 2 0 350 3 4 5 3 5 5 a mm 2 6 1 5 6 M12 a Make sure not to cover the drain holes In any case make sure the unit...

Страница 30: ...the following illustration field supply 2 Place the 2 cables over the outdoor unit 3 Insert a rubber sheet between the cables and the outdoor unit to prevent the cables from scratching the paint field...

Страница 31: ...the water piping INFORMATION Also read the precautions and requirements in the following chapters General safety precautions Preparation 7 5 3 To connect the water piping Outdoor unit c b a a d c a Wa...

Страница 32: ...valve on the water inlet of the domestic hot water tank in accordance with the applicable legislation It is recommended to install a pressure reducing valve on the cold water inlet in accordance with...

Страница 33: ...domestic hot water tank Only use propylene glycol a The system does NOT contain a domestic hot water tank You can use either propylene glycol a or ethylene glycol a Propylene glycol including the nece...

Страница 34: ...rge air from the system pipe work 2 Open the cold water supply valve 3 Close all water taps after all air is purged 4 Check for water leaks 7 5 8 To insulate the water piping The piping in the complet...

Страница 35: ...que N m M4 X1M 1 2 1 5 M4 earth 7 6 5 Specifications of standard wiring components Component EPGA11 16DAV3 Power supply cable MCA a 30 7 A Voltage 230 V Phase 1 Frequency 50 Hz Wire sizes Must comply...

Страница 36: ...page 27 and 7 2 4 To open the switch box cover of the indoor unit on page 28 2 The wiring enters the unit from the top b c a d a b c Field wiring see table below d Factory mounted cable for power sup...

Страница 37: ...quired by the applicable legislation CAUTION To guarantee the unit is completely earthed always connect the backup heater power supply and the earth cable The backup heater capacity can vary depending...

Страница 38: ...t off valve 1 Connect the valve control cable to the appropriate terminals as shown in the illustration below NOTICE Wiring is different for a NC normal closed valve and a NO normal open valve X1M X2M...

Страница 39: ...ties to the cable tie mountings 7 6 15 To connect the changeover to external heat source 1 Connect the changeover to external heat source cable to the appropriate terminals as shown in the illustrati...

Страница 40: ...OTICE When closing the indoor unit cover make sure that the tightening torque does NOT exceed 4 1 N m 8 Configuration 8 1 Overview Configuration This chapter describes what you have to do and know to...

Страница 41: ...03 04 05 06 07 08 09 0A 0B 0C 0D 0E 1 6 Press the left dial to confirm the new setting 7 Press the center button to go back to the home screen INFORMATION When you change the overview settings and you...

Страница 42: ...mode active a3 Measured ambient temperature Item Description Indoor unit domestic hot water tank b1 b2 b1 Indoor unit Floor standing indoor unit with integrated tank Wall mounted indoor unit with sep...

Страница 43: ...y for the installer Perform tests and maintenance User profile Change the active user profile Operation Turn heating cooling functionality and domestic hot water preparation on or off 8 3 4 Menu scree...

Страница 44: ...ng schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 Prerequisite The room temperature schedule is only available if room thermostat control is active If leaving water temperature control is active...

Страница 45: ...the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select the Rename option Delete Rename 3 Browse through the character list and confirm the selected character 4 Confirm t...

Страница 46: ...utomatic In case of one leaving water temperature zone If Then Space heating cooling is OFF and the outdoor ambient temperature drops below 4 C The unit will supply leaving water to the heat emitters...

Страница 47: ...custom Code Description 2 1 N A Schedule 0 No 1 Yes Heating schedule You can set the main zone heating temperature schedule using the schedule screen For more information about this screen see 8 3 8 S...

Страница 48: ...aximum of the 2 zones CAUTION If there are 2 zones it is important that the zone with the lowest water temperature is configured as the main zone and the zone with the highest water temperature is con...

Страница 49: ...only 1 digital input X2M 35 Select this value in case of a connection to the heat pump convector FWXV 2 2 contacts The used external room thermostat can send a separate heating cooling thermo ON OFF c...

Страница 50: ...etween the desired and the actual room temperature This creates a better match between the capacity of the heat pump and the actual required capacity and results in less start stop cycles and a more e...

Страница 51: ...mode of the additional zone can be independently set from the setpoint mode of the main zone see Main zone on page 47 Code Description 3 4 N A Setpoint mode 0 Fixed 1 WD heating fixed cooling 2 Weathe...

Страница 52: ...e lowest leaving water temperature in cooling operation 3 8 1 9 05 Heating minimum 15 C 37 C Code Description 3 8 2 9 06 Heating maximum 2 0D 2 emitter type additional zone radiator 37 C 60 C Else 37...

Страница 53: ...YS be within the operation range determined by the Space heating off temperature and the Space cooling off temperature If the outdoor temperature drops the operation mode will switch to cooling and vi...

Страница 54: ...damage to the heat emitters CAUTION If there are 2 zones and the emitter types are wrongly configured water of high temperature can be sent towards a low temperature emitter underfloor heating To avo...

Страница 55: ...e When there is heating output the pump speed is only determined by delta T in relation to the required capacity With this limitation range delta T is possible and the comfort is guaranteed The maximu...

Страница 56: ...ration is active the risk of space heating cooling and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating cooling interr...

Страница 57: ...ver rise above a set maximum value This maximum allowable hot water temperature shall be selected according to the applicable legislation CAUTION Be sure that the disinfection function start time 5 7...

Страница 58: ...eather dependent according to the weather dependent curve During weather dependent operation the end user cannot adjust the desired tank temperature on the user interface Also see 8 3 7 Detailed scree...

Страница 59: ...heck if holiday mode is activated and or running If is activated on the home screen holiday mode is active To configure the holiday 1 Activate the holiday mode Go to 7 3 1 User settings Holiday Activa...

Страница 60: ...taken into account when setting the energy prices Although the running cost can increase the total operation cost taking into account the reimbursement will be optimized NOTICE Make sure to modify the...

Страница 61: ...ter pump d Heater element e Non return valve f Shower g Cold water h Domestic hot water OUT i Recirculation connection DHW pump schedule Here you can program a schedule for the DHW pump only for field...

Страница 62: ...peration then set 4 00 to 2 Emergency Emergency When the heat pump fails to operate the backup heater can serve as an emergency heater and either automatically or non automatically take over the heat...

Страница 63: ...04 When Control Room thermostat This preset value is only taken into account if there is a request for space heating or cooling If there is NO request for space heating cooling the tank is heated unt...

Страница 64: ...supply is of type 1 or indoor unit is connected to a normal kWh rate power supply via X2M 5 6 and the backup heater is NOT connected to the preferential kWh rate power supply 9 8 3 D 05 Allow pump 0...

Страница 65: ...10 kWh Installed 4 100 kWh Installed 5 1000 kWh Installed 9 A 2 D 09 Electricity meter 2 0 None NOT installed 1 1 10kWh Installed 2 1 kWh Installed 3 10 kWh Installed 4 100 kWh Installed 5 1000 kWh In...

Страница 66: ...ive If the outdoor temperature Then Space heating by the heat pump system Bivalent signal for the auxiliary boiler is Drops below Tcalc Stops Active Rises above Tcalc 3 C Starts Inactive INFORMATION T...

Страница 67: ...independent of the preferential kWh rate power supply status by connecting the indoor unit to a normal kWh rate power supply Code Description 9 E C 09 Auto restart 0 Manual 1 Automatic Disable protect...

Страница 68: ...er settings Language Time date Holiday Quiet Electricity price Gas price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 E...

Страница 69: ...upply Benefit kWh power supply Allow heater Allow pump 9 2 Domestic hot water Domestic hot water DHW pump DHW pump schedule Solar 9 9 Power consumption control Power consumption control Type Limit Lim...

Страница 70: ...can the unit be powered up You read the complete installation instructions as described in the installer reference guide The indoor unit is properly mounted The outdoor unit is properly mounted The f...

Страница 71: ...issioning Air purge 3 In the menu set Type Manual 4 Select Start air purge 5 Select OK to confirm Result The air purge starts It will stop automatically when air purge cycle is finished 6 During manua...

Страница 72: ...X2M 31 See 7 6 8 To connect the main power supply on page 37 INFORMATION If Emergency is set to Manual A 6 C 0 and the unit is triggered to start emergency operation the user interface will ask confir...

Страница 73: ...eration switch off or a power failure you can read out the underfloor heating screed dryout status 1 Go to A 4 3 Commissioning UFH screed dryout Status 2 You can read out the value here Stopped at the...

Страница 74: ...1 5 2 To clean the water filter in case of trouble on page 75 11 5 3 To install the water filter on page 76 Water pressure relief valve Open the valve and check if it operates correctly The water may...

Страница 75: ...le on page 75 11 5 3 To install the water filter on page 76 11 5 1 To remove the water filter Prerequisite Stop the unit operation via the user interface operation switch Prerequisite Turn OFF the res...

Страница 76: ...needed 12 Troubleshooting 12 1 Overview Troubleshooting This chapter describes what you have to do in case of problems It contains information about Solving problems based on symptoms Solving problem...

Страница 77: ...he problem persists after you have conducted all of the above checks contact your dealer Possible causes Corrective action The preferential kWh rate power supply settings and electrical connections do...

Страница 78: ...s Possible causes Corrective action The backup heater operation is not activated Check and make sure that The backup heater operation mode is enabled Go to 9 3 8 Installer settings Backup heater Opera...

Страница 79: ...guideline for each error please see the service manual 12 4 1 To display the help text in case of a malfunction In case of a malfunction the following will appear on the home screen depending on the s...

Страница 80: ...temperature thermistor Abnormality outdoor unit J6 33 Sensor communication error J7 12 Brine inlet thermistor abnormality Error code Detailed error code Description J8 00 Malfunction of refrigerant li...

Страница 81: ...door unit 13 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST b...

Страница 82: ...essure for at least 1 hour 5 If you do NOT reach the target vacuum or CANNOT maintain the vacuum for 1 hour do the following Check for leaks again Perform vacuum drying again INFORMATION After opening...

Страница 83: ...ing the stop valve tighten the stem cap and check for refrigerant leaks Item Tightening torque N m Stem cap liquid side 13 5 16 5 Stem cap gas side 22 5 27 5 13 5 4 To handle the service cap ALWAYS us...

Страница 84: ...E 300 300 300 300 300 1000 150 150 150 150 150 150 150 1000 1000 1000 500 HD HU HD HU HB HU HD HU HB HU a b c d e eB eD A B C D E HB HU HD A C Left side and right side obstacles walls baffle plates B...

Страница 85: ...er m Accumulator n Economiser heat exchanger o Inverter PCB heat sink p Plate heat exchanger E1H Crankcase heater M1C Compressor M1F Upper fan motor M2F Lower fan motor R1T Thermistor outdoor air R2T...

Страница 86: ...d water IN loose nut 3 4 b2 Domestic hot water hot water OUT loose nut 3 4 c1 Water IN connection c2 Water OUT connection d Pump e Backup heater f Shut off valve male female 1 if equipped g Expansion...

Страница 87: ...d English Translation Legend Legend Field supply Field supply English Translation Optional Optional Part n Part n Description Description A1P Printed circuit board main A2P Printed circuit board noise...

Страница 88: ...1D V4D A1P Diode V1R A1P IGBT power module V2R A1P Diode module V1T V3T A1P Insulated Gate Bipolar Transistor IGBT X1M Terminal strip Y1E Electronic expansion valve main Y3E Electronic expansion valve...

Страница 89: ...ditional leaving water temperature On OFF thermostat wired On OFF thermostat wired On OFF thermostat wireless On OFF thermostat wireless Ext thermistor External thermistor Heat pump convector Heat pum...

Страница 90: ...mostat Inrush Inrush current Max load Maximum load Normally closed Normally closed Normally open Normally open Safety thermostat contact 16 V DC detection voltage supplied by PCB Safety thermostat con...

Страница 91: ...2 core signal signal 2 core 2 core 2 core signal 2 core 2 core External sensor floor or ambient Only for KRTETS signal 2 core 3m included A13P P1 P2 LAN adapter A14P P1 P2 user interface Only for BRC...

Страница 92: ...n who is owner of the product and or operates the product Applicable legislation All international European national and local directives laws regulations and or codes that are relevant and applicable...

Страница 93: ...ble indoor units EABH16DA6V EABH16DA9W EABX16DA6V EABX16DA9W EAVH16S18DA6V EAVH16S23DA6V EAVH16S18DA9W EAVH16S23DA9W EAVX16S18DA6V EAVX16S23DA6V EAVX16S18DA9W EAVX16S23DA9W Notes 1 6V 2 9W 3 AB 4 EAV...

Страница 94: ...2 R W 10 25 C step 1 C 15 C 3 5 0 03 R W 40 5 C step 1 C 10 C Cooling WD curve 3 6 0 04 R W 9 07 9 08 C step 1 C 8 C 3 6 0 05 R W 9 07 9 08 C step 1 C 12 C 3 6 0 06 R W 25 43 C step 1 C 35 C 3 6 0 07...

Страница 95: ...abled 1 Enabled Tank 5 2 6 0A R W 30 6 0E C step 1 C 60 C 5 3 6 0B R W 30 min 50 6 0E C step 1 C 45 C 5 4 6 0C R W 30 min 50 6 0E C step 1 C 45 C 5 6 6 0D R W 0 Reheat only 1 Reheat sched 2 Scheduled...

Страница 96: ...1 2 0D R W 0 Underfloor heating 1 Fancoil unit 2 Radiator 9 1 R W 0 Fixed 1 WD heating fixed cooling 2 Weather dependent 9 1 R W 0 No 1 Yes 9 1 0 00 R W 9 05 min 45 9 06 C step 1 C 35 C 9 1 0 01 R W 9...

Страница 97: ...0 20 C step 1 C 10 C 9 6 4 8 02 R W 0 10 hour step 0 5 hour 0 5 hour E 07 1 3 hour E 07 1 9 6 5 8 00 R O 0 20 min step 1 min 1 min 9 6 6 8 01 R W 5 95 min step 5 min 30 min 9 6 7 8 04 R W 0 95 min ste...

Страница 98: ...1 01 R W 10 25 C step 1 C 15 C 9 I 1 02 R W 9 01 9 00 step 1 C 35 C 9 I 1 03 R W 9 01 min 45 9 00 C step 1 C 25 C 9 I 1 04 R W 0 Disabled 1 Enabled 9 I 1 05 R W 0 Disabled 1 Enabled 9 I 1 06 R W 10 2...

Страница 99: ...15 35 C step 1 C 0 C Water pipe freeze prevention What is the desired delta T in heating for the additional zone What is the desired delta T in heating for the main zone What is the desired delta T i...

Страница 100: ...I 8 08 R W 9 03 9 02 step 1 C 20 C 9 I 8 09 R W 9 01 9 00 step 1 C 35 C 9 I 8 0A R W 9 01 9 00 step 1 C 33 C 9 I 8 0B 13 9 I 8 0C 10 9 I 8 0D 16 What is the capacity of the backup heater step 2 Space...

Страница 101: ...pulse kWh 5 1000 pulse kWh 9 I D 0A 0 9 I D 0B 2 9 I E 00 R O 0 5 0 LT split 9 I E 01 R O 1 9 I E 02 R W 5 R O 6 0 Reversible 5 1 Heating only 6 9 I E 03 R O 3 6V 1 4 9W 2 What is the maximum desired...

Страница 102: ...ed 9 I F 0A 0 9 I F 0B R W 0 No 1 Yes 9 I F 0C R W 0 No 1 Yes 9 I F 0D R W 0 Continuous 1 Sample 2 Request Is the power saving function available on the outdoor unit Pump operation allowed outside ran...

Страница 103: ......

Страница 104: ...4P556070 1 2019 02 Copyright 2018 Daikin...

Отзывы: