6.2

Symptom: You are feeling too cold
(hot) in your living room

Possible cause

Corrective action

The desired room temperature is
too low (high).

Increase (decrease) the desired
room temperature. See

"3.3.2 Room thermostat control -
Using the room temperature
home pages" 

[

4

 6].

If the problem recurs daily, do
one of the following:

▪ Increase  (decrease)  the  room

temperature  preset  value.  See
the user reference guide.

▪ Adjust  the  room  temperature

schedule. See 

"3.5 Schedules:

Example" 

[

4

 7].

The desired room temperature
cannot be reached.

Increase the desired leaving
water temperature in accordance
with the heat emitter type. See

"3.3.3 Room thermostat control -
Using the leaving water
temperature home pages" 

[

4

 6].

The weather-dependent curve is
set incorrectly.

Adjust the weather-dependent
curve. See the user reference
guide.

6.3

Symptom: The water at the tap is
too cold

Possible cause

Corrective action

You ran out of domestic hot
water because of unusual high
consumption.

If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy. See

"3.4.5 Using the DHW tank
booster mode" 

[

4

 7].

If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally. See 

"To

read out and overrule the active
or next scheduled desired
temperature (in scheduled mode
or sch reheat
mode)" 

[

4

 7].

If the problem recurs daily, do
one of the following:

▪ Increase 

the 

DHW 

tank

temperature  preset  value.  See
the user reference guide.

▪ Adjust 

the 

DHW 

tank

temperature 

schedule.

Example: 

Program 

to

additionally 

heat 

up 

the

DHW  tank  to  a  preset  value
(

Storage  eco

  =  lower  tank

temperature)  during  the  day.
See 

"3.5 

Schedules:

Example" 

[

4

 7].

The desired DHW tank
temperature is too low.

6.4

Symptom: Heat pump failure

When  the  heat  pump  fails  to  operate,  the  backup  heater  can  serve
as  an  emergency  heater  and  either  automatically  or  non-
automatically take over the heat load.

▪ When  auto  emergency  is 

activated

  and  a  heat  pump  failure

occurs,  the  backup  heater  will  automatically  take  over  the  heat
load.

▪ When  auto  emergency  is 

not  activated

  and  a  heat  pump  failure

occurs, the domestic hot water and space heating operations will
stop  and  need  to  be  recovered  manually.  The  user  interface  will
then ask you to confirm whether the backup heater can take over
the heat load or not.

When the heat pump fails,   will appear on the user interface.

Possible cause

Corrective action

Heat pump is damaged.

▪ Press 

 to view a description

of the problem.

▪ Press 

 again.

▪ Select 

  to  allow  the  backup

heater  to  take  over  the  heat
load.

▪ Call  your  local  dealer  to  get

the heat pump fixed.

INFORMATION

When  the  backup  heater  takes  over  the  heat  load,
electricity consumption will be considerably higher.

6.5

Symptom: The system is making
gurgling noises after
commissioning

Possible cause

Corrective action

There is air in the system.

Purge air from the system.

(a)

Various malfunctions.

Check if   is displayed on the
home pages of the user
interface. You can press 

 to

display more information about
the malfunction.

(a)

We recommend to purge air with the air purge function
of the unit (to be performed by the installer). If you purge
air from the heat emitters or collectors, mind the
following:

WARNING

Air  purging  heat  emitters  or  collectors.

  Before  you

purge air from heat emitters or collectors, check if an error
or   is displayed on the home pages of the user interface.

▪ If not, you can purge air immediately.

▪ If  yes,  make  sure  that  the  room  where  you  want  to

purge air is sufficiently ventilated. 

Reason:

 Refrigerant

might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.

7

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

Содержание Altherma 3 R F

Страница 1: ...Operation manual Daikin Altherma 3 R F English Operation manual Daikin Altherma 3 R F EHFZ03S18DJ3V...

Страница 2: ...4 Symptom Heat pump failure 9 6 5 Symptom The system is making gurgling noises after commissioning 9 7 Disposal 9 8 Glossary 10 1 Installer settings Tables to be filled in by installer 1 1 Quick wizar...

Страница 3: ...n of the installation good practices reference data Format Digital files on http www daikineurope com support and manuals product information Addendum book for optional equipment Additional info about...

Страница 4: ...rature home page Desired room temperature according to the selected schedule On the DHW tank temperature home page DHW tank mode Scheduled mode DHW tank mode Reheat mode DHW tank mode Scheduled reheat...

Страница 5: ...unning hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Tempera...

Страница 6: ...lue but will return to the scheduled value at the next scheduled action To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room...

Страница 7: ...ther dependent you cannot change it on the home page 3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode user profile Basic 1 Go to the DHW tank temperature home page Tank 2 Pr...

Страница 8: ...water pump only during periods of the day when instant hot water is necessary Example In the morning and evening 5 Maintenance and service 5 1 Overview Maintenance and service The installer has to per...

Страница 9: ...eater can serve as an emergency heater and either automatically or non automatically take over the heat load When auto emergency is activated and a heat pump failure occurs the backup heater will auto...

Страница 10: ...FZ03S18DJ3V Daikin Altherma 3 R F 4P596819 1 2019 10 8 Glossary DHW Domestic hot water Hot water used in any type of building for domestic purposes LWT Leaving water temperature Water temperature at t...

Страница 11: ......

Страница 12: ...4P596819 1 2019 10 Copyright 2019 Daikin 4P383117 1 D 0000000 4P596819 1 0000000 Verantwortung f r Energie und Umwelt...

Отзывы: