Daikin Altherma 3 R F Скачать руководство пользователя страница 8

4 Energy saving tips

Operation manual

8

EHFZ03S18DJ3V

Daikin Altherma 3 R F

4P596819-1 – 2019.10

4

Energy saving tips

Tips about room temperature

▪ Make sure the desired room temperature is NEVER too high, but

ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.

▪ Do  NOT  increase  the  desired  room  temperature  to  speed  up

space heating. The space will NOT heat up faster.

▪ When  your  system  layout  contains  slow  heat  emitters  (example:

under  floor  heating),  avoid  large  fluctuation  of  the  desired  room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.

▪ Use  a  weekly  schedule  for  your  normal  space  heating  needs.  If

necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature. 

Example: 

When  you  have  a  party,  or  when  you

are leaving for a couple of hours.

▪ For  longer  periods:  You  can  use  the  holiday  mode. 

Example:

When  you  stay  at  home  during  your  holiday,  or  when  you  go
away during your holiday.

▪ Use  a  weekly  schedule  for  your  normal  space  heating  needs.  If

necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature  until  the  next  scheduled  action. 

Example: 

When

you have a party, or when you are leaving for a couple of hours.

▪ For longer periods: You can use the holiday mode.

Tips about DHW tank temperature

▪ Use a weekly schedule for your normal domestic hot water needs

(only in scheduled mode).

▪ Program  to  heat  up  the  DHW  tank  to  a  preset  value  (

Storage

comfort

  =  higher  DHW  tank  temperature)  during  the  night,

because then space heating demand is lower.

▪ If  heating  up  the  DHW  tank  once  at  night  is  not  sufficient,

program to additionally heat up the DHW tank to a preset value
(

Storage eco

 = lower DHW tank temperature) during the day.

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

5

Maintenance and service

5.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

As end user, you have to:

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg] / 1000

Please contact your installer for more information.

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

5.2

To find the contact/helpdesk
number

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go  to  [6.3.2]: 

  > 

Information

  > 

Error  handling

  >

Contact/helpdesk number

.

6

Troubleshooting

6.1

To check the error history

Prerequisite: 

Only available if   is displayed on the home pages.

1

Go  to  [6.3.1]: 

  > 

Information

  > 

Error  handling

  > 

Error

history

.

Содержание Altherma 3 R F

Страница 1: ...Operation manual Daikin Altherma 3 R F English Operation manual Daikin Altherma 3 R F EHFZ03S18DJ3V...

Страница 2: ...4 Symptom Heat pump failure 9 6 5 Symptom The system is making gurgling noises after commissioning 9 7 Disposal 9 8 Glossary 10 1 Installer settings Tables to be filled in by installer 1 1 Quick wizar...

Страница 3: ...n of the installation good practices reference data Format Digital files on http www daikineurope com support and manuals product information Addendum book for optional equipment Additional info about...

Страница 4: ...rature home page Desired room temperature according to the selected schedule On the DHW tank temperature home page DHW tank mode Scheduled mode DHW tank mode Reheat mode DHW tank mode Scheduled reheat...

Страница 5: ...unning hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Tempera...

Страница 6: ...lue but will return to the scheduled value at the next scheduled action To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room...

Страница 7: ...ther dependent you cannot change it on the home page 3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode user profile Basic 1 Go to the DHW tank temperature home page Tank 2 Pr...

Страница 8: ...water pump only during periods of the day when instant hot water is necessary Example In the morning and evening 5 Maintenance and service 5 1 Overview Maintenance and service The installer has to per...

Страница 9: ...eater can serve as an emergency heater and either automatically or non automatically take over the heat load When auto emergency is activated and a heat pump failure occurs the backup heater will auto...

Страница 10: ...FZ03S18DJ3V Daikin Altherma 3 R F 4P596819 1 2019 10 8 Glossary DHW Domestic hot water Hot water used in any type of building for domestic purposes LWT Leaving water temperature Water temperature at t...

Страница 11: ......

Страница 12: ...4P596819 1 2019 10 Copyright 2019 Daikin 4P383117 1 D 0000000 4P596819 1 0000000 Verantwortung f r Energie und Umwelt...

Отзывы: