![Daikin Altherma 3 R F Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/daikin/altherma-3-r-f/altherma-3-r-f_operation-manual_3215396007.webp)
3 Operation
Operation manual
7
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596819-1 – 2019.10
t
60°C
00:00
07:00
50°C
15°C
40°C
14:00
21:00
1
2
3
4
5
Tt
T
t
Domestic hot water tank temperature
t
Time
3.4.3
Sch reheat mode
In sch reheat mode ( ), the domestic hot water control is
the same as in scheduled mode. However, when the DHW tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis value; example: 35°C), the DHW tank heats up until it
reaches the reheat set point (example: 45°C). This ensures that a
minimum amount of hot water is available at all times.
Example:
t
Tt
60°C
00:00
07:00
50°C
45°C
15°C
14:00
21:00
35°C
1
2
4
5
3
T
t
Domestic hot water tank temperature
t
Time
3.4.4
Using the DHW tank temperature home
page
Typical DHW tank temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. The examples in the illustrations
below are in DHW tank mode = Scheduled.
User profile =
Basic
User profile =
Detailed
15:20
60°C
Storage comfort
Tank
Mon
15:20
60°C
00:00
Mon
Tue
Tank
Storage comfort
To read out and adjust the desired reheat temperature (in
scheduled and reheat mode)
1
Go to [7.4.3.3]:
>
User settings
>
Preset values
>
Tank
temperature
>
Reheat
.
Result:
You can read out the desired reheat temperature.
2
Press
or
to adjust.
To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or sch reheat mode)
1
Go to the DHW tank temperature home page (
Tank
).
Result:
60°C
is displayed.
2
Press
or
to overrule.
Note:
If the desired temperature is weather dependent, you cannot
change it on the home page.
3.4.5
Using the DHW tank booster mode
To activate the DHW tank booster mode (user profile = Basic)
1
Go to the DHW tank temperature home page (
Tank
).
2
Press
for more than 5 seconds.
To activate the DHW tank booster mode (user profile = Detailed)
1
Go to the DHW tank temperature home page (
Tank
).
2
Press
to select .
3.5
Schedules: Example
INFORMATION
The procedures to program other schedules are similar.
In this example:
▪ Monday = Tuesday = Wednesday = Thursday = Friday
▪ Saturday = Sunday
To program the schedule
1
Select
Empty
and press
.
2
Program the schedule for Monday. See below for more details.
3
Copy from Monday to Tuesday, Wednesday, Thursday and
Friday. See below for more details.
4
Program the schedule for Saturday.
5
Copy from Saturday to Sunday.
6
Save the schedule and give it a name. See below for more
details.
To program the schedule for Monday
1
Use
and
to select Monday.
2
Press
to enter the schedule for Monday.
3
Program the schedule for Monday:
▪ Use
and
to select an entry.
▪ Use
and
to change the value of an entry.
To copy from one day to another
1
Select the day from which you want to copy and press
.
Example:
Monday.
2
Select
Copy day
and press
.
3
Set the days you want to copy to
Yes
and press
.
Example:
Tuesday =
Yes
, Wednesday =
Yes
, Thursday =
Yes
and Friday
=
Yes
.
To save the schedule
1
Press
, select
Save schedule
and press
.
2
Change the name and press
. (Only applicable for room
temperature schedules).
Example:
MyWeekSchedule
To select which schedule you currently want to use
1
Go to [5]:
>
Select schedules
.
2
Select for which control you want to use a schedule.
Example:
[5.1]
Room temperature
.
3
Select for which operation mode you want to use a schedule.
Example:
[5.1.1]
Heating
.
4
Select a predefined or user‑defined schedule and press
.