7
Installation
Pr
ocedure
Installation
Main machine (Machining center)
Power line
Circuit breaker
Power line
Signal
Main machine (Machining center)
Power line
Main machine (Machining center)
Circuit breaker
Remote control switch
Circuit breaker
Control panel
Electric Wiring
n
Conduct electric wiring according to the local wiring standard.
n
The Oil Cooling Unit (except for the “–B” model) is not equipped with a circuit breaker. A circuit breaker exclusively for the unit
should be mounted to the main machine.
n
For electric wiring, refer to the electric wiring diagram on the nameplate attached to the rear of the electrical equipment box cover.
n
Do not change the wiring in the Oil Cooling Unit. Do not touch the protection devices.
To turn ON the power supply for the Oil Cooling Unit, the following three methods are available:
When the circuit breaker for the main machine is turned ON, the Oil Cooling Unit starts operation. To stop the unit, turn
OFF the circuit breaker for the main machine.
Directly starting/stopping the Oil Cooling Unit with the main machine power supply
Starting/stopping the Oil Cooling Unit
When the remote control switch is turned ON, the Oil Cooling Unit starts operation. To stop the unit, turn OFF the remote
control switch.
Starting/stopping the Oil Cooling Unit with the remote control contact (see page )
If you keep pressing the and keys for at least 2 seconds in the “operation lock” mode, the Oil Cooling Unit starts
operation according to preset conditions. If you keep pressing the and keys for at least 2 seconds during
operation, “Loc” blinks on the data display, and the Oil Cooling Unit will be stopped (locked).
Starting/stopping the Oil Cooling Unit with the control panel
9