35
Optional
Functions
Optional P
a
rt
s
For AKZ8-OP-Y
R1/8
(4.5)
Lead wire
DB619-121 or equivalent
27.5
80
SXH-001T-0.6
(5)
XHP-3 (Blue)
Optional Parts
Returned oil temperature control
When the following optional parts are mounted to the oil piping (return oil piping) of the main machine, the Oil Cooling Unit can
perform control by detecting the returned oil temperature.
Substitute the blue connector (XHP-3) of the above part for the blue connector [CN11] of the outlet oil temperature thermistor in
the electrical equipment box. (See “Outline of electrical equipment box” on page .)
See page .
Optional parts
Mounting procedure
Type
Lead wire
length
L (m)
Name
Dimensions
Application
(Installed by user)
Compatible model
AKZ8–OP–Y10
AKZ8–OP–Y5
For returned oil
temperature control
(Mounted to main
machine oil piping)
AKZ8 series
Oil temper
ature
control ther
mistor
Oil Cooling Unit
Main machine
(10 m)
(5 m)
Rc 1/8 Screw seat
Oil piping
Connection to control board connector [CN11] of Oil Cooling Unit
Substitution for outlet oil temperature thermistor,
Operation in outlet oil temperature control mode No. 1, 5 or 6.
19
Characteristics of thermistor: Resistance R25 (resistance at 25˚C) = 20 k
Ω
, Tolerance: ±2%
9
PIM00116C_EN.fm 35 ページ 2008年9月29日 月曜日 午前11時51分