Si12-411A
Outdoor Unit (80 / 90 Class)
Removal Procedure
221
1.2
Removal of
Propeller Fans
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the discharge
outlet grill
1
To take off propeller
fan, remove the
washer-fitted nut M8.
2
Remove the propeller
fan.
For reassembling, align
mark of propeller fan with
D-cut section of motor shaft.
Mount the propeller fan while
positioning
mark to the
top.