6-3
Chapter 6
W
elding Condition
L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
F19
Alarm setting switching
OFF/ON
OFF
Sets the output status when an error of the alarm
level is detected:
OFF: Ineffective
ON: Stops the output
-
F20
Low input voltage
detection level
260 to 400
320 (V)
Adjusts the low primary input voltage detection
level.
-
F21
Maximum cooling fan
operation
OFF/ON
OFF
Sets the operation mode of cooling fan:
OFF: Economical operation
ON: Rotates the fan at maximum speed at all time
-
F22
Operation sound switching
OFF/ON
ON
Sets the operation sound when any key is pressed
on the operation panel:
OFF: Turns off the sound
ON: Turns on the sound
-
F23
Sleep mode
switching time
0 to 10
0
Sets the time until the welding power source
enters into sleep mode:
0: OFF
1 to 10: 1 min to 10 min
-
F24
Wire feeding speed setting
OFF/ON
OFF
Sets the criteria for welding condition:
OFF: based on current
ON: based on wire feeding speed
-
F25
External output 1 setting
0
0
Used when connecting with automatic machine
made by other manufacturer.
-
F26
External output 2 setting
F27
External output 3 setting
F28
External output 4 setting
F29
External input 1 setting
0 to 9
0
Sets the functions of input terminal of the
programmable I/O.
-
F30
External input 2 setting
0
F31
External input 3 setting
0
F32
External input 4 setting
0
F33
Inhibition ratio display for
[squeeze] detection
-
-
When F33 is selected, the [Squeeze] detection
inhibition ratio (%) is displayed on the right digital
meter.This function is not configurable.
-
F34
Automatic correction of
[squeeze] detection
sensitivity
OFF/ON
ON
Sets ON/OFF of the automatic correction function
of the [Squeeze] detection sensitivity:
OFF: No automatic correction
ON: With automatic correction
○
F35
Saving [squeeze]
detection sensitivity
OFF/ON
OFF
Sets whether to save the [Squeeze] detection
sensitivity at completion of welding:
OFF: Not to save
ON: To save until the next welding starts
○
F36
Spatter control P1P
-100 to +100
0
Sets the control parameters for spatter control.
○
F37
Spatter control P2P
F38
Arc voltage direct detection
switching
OFF/ON
OFF
Sets the voltage direct detecting terminal on the
base metal side of the welding power source and
voltage detection terminal of the wire feeder.
OFF: ineffective
ON: effective
-
F39
Current display adjustment
(GAIN)
-20 to 20
0 (%)
Adjusts the current values displayed on the digital
meter.
-
F40
Current display adjustment
(OFFSET)
-20 to 20
0 (A)
F41
Voltage display adjustment
(GAIN)
-20 to 20
0 (%)
Adjusts the voltage values displayed on the digital
meter.
-
F42
Voltage display adjustment
(OFFSET)
-2.0 to 2.0
0.0 (V)
F43
CAN ID
1 to 16
1
Sets CAN ID numbers to be used in the PC
monitoring system, etc.
-
No.
Function Name
Setting range
Initial value
Explanation
Memory
Содержание OTC Welbee P500L
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO...
Страница 142: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 16...