10. OPERATION
(Continued)
10.2.5 Recovery method for Initial Values
The welding condition being used (including internal functions) can restore to their initial values
completely without any effect to the stored welding conditions. To restore the initial values, first
turn off the power switch, then press (keep pressing) DISPLAY CHANGE key [7] and GAS
CHECK key[10] at the same time, and then turn on the power switch. After power-up and “End”
being displayed as shown in the figure below, release the keys, turn off the power switch and
then turn it on again.
The status after initialization
See section “14.3 initial value and setting range” about initial values for all parameters and
functions.
10.2.6 Confirming Software Version
To confirm the software version installed in the power source, keep pressing DISPLAY
CHANGE key [7] and turn on the power switch. After power-up, the digital meters will display
the current software version number installed.
(example)
Left and right: “P30110”
←Display software number
↓ Press DISPLAY CHANGE key[7] again.
Left:
“0 0 2” ←Display major version (Ver. 002)
Right:
“4 0 7” ←Display minor version
↓ Press DISPLAY CHANGE key[7] again.
Left:
“– – –”
Right:
“0 0 0” ←Display combination
↓ Press DISPLAY CHANGE key[7] again.
The power supply will start up normally and get ready to performing welding.