60
-
11. APPLIED FUNCTION
(Continued)
11.2 Combining with an Automatic Machine
When combining with an automatic machine, connect the welding power source to an auto-welding
machine through external connection using the internal 12P terminal block (TM4), the socket for
remote control box and the socket for wire feeder . Refer to section “11.1 External Connection inside
Terminal Block” about the 12P terminal block.
(1) Setting of current, voltage and inching signals
When connecting a self-made remote-control box, use a potentiometer R12 made for setting
current, a potentiometer R13 made for setting voltage and the wire feeding switch PB that are
specified in “13.1 PARTS LIST”. Refer to the figure below for wiring.
In addition, internal function F4 must be set to “1” to switch to “Auto” mode for setting current and
voltage by external voltage signal. Refer to “10.2.1 (4) Switch of Auto/Semi-auto Mode” for more
details.
(2) Starting Signal
Welding is carried out by the start signal when terminals 1 and 2 of CON2 are short-circuited.
Welding stops when the terminals are open.
CON2
CON1
Starting Signal
CON2
Remote Control Box
CON1
Current Setting
Voltage Setting
Inching