Daihan Scientific MaXtable H20 Скачать руководство пользователя страница 1

Man236 (15 Jun. 2016)

High Performance Dry Bath

Heating Block

.

Certifications by 

- - -

ISO 9001 Certified.
Validation(IQ&OQ) Service.

Patented(Patent No. 10-0554098)  Jog Shuttle Control System.

User Manual

(Version 2.2.1)

written for

MaXtable

TM

H20

    "MaXtable

TM

H20” High Performance Dry Bath-Heating Block.

DAIHAN-Sci.com or 

ALL

for

LAB.com

Shopping Mall

Sales & Basic A/S :

By the Nearest Official Distributors.

Содержание MaXtable H20

Страница 1: ...ed Validation IQ OQ Service Patented Patent No 10 0554098 Jog Shuttle Control System User Manual Version 2 2 1 written for MaXtableTM H20 MaXtableTM H20 High Performance Dry Bath Heating Block DAIHAN...

Страница 2: ...Use 3 1 2 Product Introduction 4 1 3 Product Configuration 5 2 Installation 2 1 Product Installation 6 2 2 Product Specifications 7 3 Product Usage 3 1 Precautions for Use 10 3 2 Names of Each Part 1...

Страница 3: ...he meaning Warning If the product is mishandled while ignoring this symbol the danger by which human beings are dead or severely injured may occur Caution Failure to follow the instructions may result...

Страница 4: ...r entire interval of broad range of temperature The product thus can be applicable to various labs in diverse disciplines and has the following features 1 The Digital Feedback Control controlled by th...

Страница 5: ...product is furnished with functions capable of protecting the overheating overcurrent and sensor errors of the product to secure the safety of users 9 The product is furnished with various kinds of b...

Страница 6: ...together with the product is damaged and connect it with the product 4 Insert the socket in the other side into the wall plug In case of using a power strip be careful not to exceed the electrical en...

Страница 7: ...uct Specifications Models MaXtableTM H20 Only Unit MaXtable TM H20 set included Standard Block Controller Single Digital Fuzzy Controller Useful Block Interchangeable Block 90 120 h60mm for Various Tu...

Страница 8: ...t may cause overheating or electrical fault of the product This product was manufactured to move normally at the rated voltage Confirm the voltage state before the installation of product AC 230V 50 6...

Страница 9: ...ve sufficient electric capacity The fluctuation of main power voltage should be lower than 10 of the nominal voltage Please separate the power plug from the outlet for safety when the product is unuse...

Страница 10: ...the product to other place Please wear the protective equipment because the heating temperature can be overheated above the setting temperature Please always use the safety equipment working clothes...

Страница 11: ...ion Power Switch Equipment power ON OFF Fuse Holder Fixing the fuse and protection not to expose Specification sticker Recording the specification and serial number of product Safety symbol sticker De...

Страница 12: ...on Mode change button Timer setting mode Temperature setting mode Locking mode LCD Display Display operation information Rotary Switch Turn the clockwise or counterclockwise to adjust the setting valu...

Страница 13: ...The range of values of the time set by the timer can be up to 99 time and 59 minutes and the set value will be varying by a unit of 1 minutes 6 Push the Rotary Switch once and shortly then the product...

Страница 14: ...se to adjust the set value Press the PUSH button to have the set value fixed on the display The Reservation Timer for reserved operation of product will then begin 4 On completion of the pre setting o...

Страница 15: ...value of current temperature whereas the figures displaying on the SV are the values of set temperature 3 Rotate the rotary switch on the controller clockwise or counterclockwise to adjust the set va...

Страница 16: ...eleasing the MODE button 3 The scope of the compensative value is 10 0 10 0 and it is possible to adjust at 0 1 unit 4 After setting the compensation value the indication of the current temperature is...

Страница 17: ...ll be changed into the display of locking mode 2 Accelerating and stop right after the locked display will prevent potential risks of malfunctioning of the product due to unintended turning of Rotary...

Страница 18: ...Centrifuge Tube 48 holes DH WHB521248 Block BLT248 for 12mm Test Tube 48 holes DH WHB521335 Block BLT335 for 13mm Test Tube 30 holes DH WHB521535 Block BLT535 for 15mm Test Tube 30 holes DH WHB521628...

Страница 19: ...y using driver Identify the fuse and replace it 120V F5AL 250V 230V F3AL 250V Re install the fuse holder to the body while pushing the holder with hands Classifications A period of checking time Day W...

Страница 20: ...sed wipe off only the part with the towel wetting with the solvent that has low freezing point 6 If the materials wetted by liquid or water are entered into this product please immediately disconnect...

Страница 21: ...t Switch off of the residual current device at the installation place or occurrence of power failure Inaccurate connection between a power plug and a socket Damage of socket plug power cable Disorder...

Страница 22: ...cess about all functions before shipment 2 This instrument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warra...

Отзывы: