38
4.5.2 Alarm Settings
4.5.2.1 Wire Zone
Set alarm settings for eight areas, and then if emergencies happen, alarms will be triggered.
Tap
, the
Alarm
interface is displayed.
Wire zone
Figure 4-42
Table 4-8 SIP server description
Parameter
Description
Area
Area numbers. There are 8 areas in total. They cannot be modified.
Type
There are 8 types of alarms: Infrared, gas sensor, smoke sensor, urgency
button, door sensor, stolen, perimeter, and doorbell. Select alarm types
according to detector types.
NO/NC
Select NO (normally open) or NC (normally closed) according to detector
types. It shall be the same as detector type.
Status
There are 5 statuses: Instant, delay, bypass, remote, and 24-hour
protection zone.
Instant: In Arm Mode, if you selected this status for an area, once
alarms are triggered, the indoor monitor will give out voice prompt
immediately.
Delay: In Arm Mode, if you selected this status for an area, once
alarms are triggered, the indoor monitor will give out voice prompt a
period later.
Bypass: If you selected the bypass status for an area, after the area
has been armed and alarms are triggered; there will be no voice