background image

                                                                           

 

 

28

Parameter  

Function  

UDP Port  

Default value is 37778. 

DNS 

Alternative DNS 

Manually set IP address of domain parse server.  

You need to enable this function if you are inputting the 
domain name in some items. Otherwise the system can not 
parse the domain name.  

Max Connection  

Network user max amount. The value ranges from 1 to 10. 

Network 
transmission QoS 

You can set the priority between fluency and video quality or 
self-adaptive. System can automatically adjust the bit stream 
or lower the resolution according to the network bandwidth. 

Advanced Set  

The advanced set interface is shown as in Figure 3-16. 

 

Figure 3-16 Advanced Set 

Please refer to the following sheet for detailed information. 

 

Содержание IPC-HDBW3300

Страница 1: ...1 HD Vandal Proof IP Dome Camera Web Operation Manual Version 1 1 ...

Страница 2: ... 2 5 Preview Window Switch 11 2 6 PTZ Control 11 2 7 Color and More Setup 14 3 Configure 16 3 1 System Information 16 3 1 1 Version Information 16 3 1 2 HDD information 16 3 1 3 Log 17 3 2 System Configuration 18 3 2 1 General Setup 18 3 2 2 Encode 20 3 2 3 Schedule 23 3 2 4 RS232 25 3 2 5 Network 27 3 2 6 Alarm 34 3 2 7 Detect 36 3 2 8 PTZ 39 3 2 9 Default Backup 40 ...

Страница 3: ...42 3 3 3 Record 42 3 3 4 Account 43 3 3 5 Auto Maintenance 44 3 3 6 Snapshot 45 3 3 7 Abnormity 45 3 4 Additional Function 47 3 4 1 Configure 47 3 4 2 Auto Register 49 3 4 3 Talk Encode 49 4 Search 51 5 Alarm 54 6 About 56 7 Log out 57 8 Appendix No IP DDNS 58 ...

Страница 4: ...efault setup z IP address 192 168 1 108 z User name admin z Password admin Please follow the steps listed below for network connection z Make sure the IPC has connected to the network properly z IPC IP address and PC IP address shall be in the same network segment IPC default IP address is 192 168 1 108 If there is router please set the corresponding gateway and subnet mask z Use order ping IP cam...

Страница 5: ...s 192 168 1 108 then please input http 192 168 1 108 in IE address column See Figure 2 1 Figure 2 1 System pops up warning information to ask you whether install webrec cab control or not Please click yes button If you can t download the ActiveX file please modify your settings as follows See Figure 2 2 Input your IP address here ...

Страница 6: ...allation the interface is shown as below See Figure 2 3 Please input your user name and password Default factory name is admin and password is admin Note For security reasons please modify your password after you first login ...

Страница 7: ...7 Figure 2 3 After you logged in IPC web main interface is shown as in Figure 2 4 ...

Страница 8: ... 1 Monitor channel 1 IPC supports main stream and extra stream z Main stream In normal network width environment main stream can record video and audio and realize network monitor z Extra stream If network width is not sufficient you can use extra stream to realize network monitor Please note the extra stream resolution shall be less than main stream resolution Open all close all Click this button...

Страница 9: ... Please refer to the following sheet for monitor window parameter information SN Parameter Function 1 4 Display device information z 1 IPC IP address z 2 Channel number z 3 Bit stream z 4 Stream decode type S1 Overlay S2 Off stream S3 GD1 H1 Overlay H2 off stream decoding from the display card 5 Digital zoom Click this button and then left drag the mouse in the zone to zoom in Right click mouse sy...

Страница 10: ...lected window is in real time monitor mode system automatically switches to playback the video by default 8 Capture picture You can snapshoot important video All images are memorized in system folder picture download default 9 Audio Turn on or off audio It has no relationship with system audio setup 10 Close video Close video in current window 11 Channel number Current view channel number 2 3 Syst...

Страница 11: ...n Figure 2 9 IPC series products do not support this function Figure 2 9 Preview Window Switch 2 6 PTZ Control Important IPC series products do not support PTZ control function Before PTZ operation please make sure you have properly set PTZ protocol Please refer to chapter 3 2 8 PTZ Here you can view direction keys speed zoom focus iris preset tour pan scan pattern aux close and PTZ setup button P...

Страница 12: ...12 Figure 2 10 PTZ Interface Click PTZ set button the interface is shown as in Figure 2 11 You can click this icon to display or hide the PTZ control platform These six buttons are for speed dome only ...

Страница 13: ... Input auto tour value and preset value Click add button you have added one preset in the tour z Repeat the above procedures you can add more presets in one tour z Or you can click delete button to remove one preset from the tour The tour value ranges from 0 to 7 It may vary due to different protocols Pattern You can input pattern value and then click start record button to begin PTZ movement Plea...

Страница 14: ... sheet for detailed information Parameter Function It is to adjust monitor video brightness It is to adjust monitor video contrast ness It is to adjust monitor video saturation Video setup It is to adjust monitor video hue Note z All the operations here apply to WEB end only z Please go to chapter 3 2 2 System configuration Encode setup color setting to adjust corresponding system items Click more...

Страница 15: ...path button system pops up an interface for you to modify path Record Path Click record path button system pops up an interface for you to modify path More Reboot Click this button system pops up a dialogue box please click OK button to reboot device ...

Страница 16: ...ion Here you can view device hardware feature and software version information See Figure 3 1 Figure 3 1 Version Information 3 1 2 HDD information Here you can view local storage status and network status including free capacity and total capacity See Figure 3 2 ...

Страница 17: ...17 Figure 3 2 HDD Information 3 1 3 Log Here you can view system log See Figure 3 3 Figure 3 3 Log Click backup button the interface is shown as in Figure 3 4 ...

Страница 18: ...n Search You can select log type from the drop down list and then click search button to view the list Clear You can click this button to delete all displayed log files Please note system does not support clear by type Backup You can click this button to backup log files to current PC 3 2 System Configuration Please click save button to save your current setup 3 2 1 General Setup Here you can set ...

Страница 19: ...19 Figure 3 5 General Setup Figure 3 6 DST Figure 3 7 DST Please refer to the following sheet for detailed information ...

Страница 20: ...ime and end time See Figure 3 6 and Figure 3 7 Language You can select the language from the dropdown list Device needs to reboot to get the modification activated HDD Full There are two options stop recording or overwrite the previous files when HDD is full Pack Duration Here you can select file size Default setup is 60 minutes Device No When you are using one remote control to manage multiple de...

Страница 21: ...21 Figure 3 8 Encode Figure 3 9 Color Setting Click watermark button you can see an interface is shown as below Figure 3 10 Watermark ...

Страница 22: ... video by default You need to check the audio box here to enable audio function Extra stream Recorded file only contains video by default You need to check the audio box here to enable audio function Resolution There are multiple resolutions You can select from the dropdown list For each resolution the recommended bit stream value is different Frame Rate PAL 1 25f s NTSC 1 30f s The frame rate may...

Страница 23: ...y mask zones Time Title z You can enable this function so that system overlays time information in video window z OSD transparent value ranges from 0 to 255 0 means complete transparent z You can use the mouse to drag the time tile position Channel Title z You can enable this function so that system overlays channel information in video window z OSD transparent value ranges from 0 to 255 0 means c...

Страница 24: ...24 Figure 3 11 Schedule Figure 3 12 Storage Set ...

Страница 25: ...e period and then select corresponding record or snapshot type motion detection snapshot and alarm snapshot Right now system does not support schedule snapshot function z Please select date Current setup applies to current day by default You can draw a circle before the week to apply the setup to the whole week z After complete setup please go back to Figure 3 11 and then click save to save curren...

Страница 26: ... keyboard COM control protocol You can use network keyboard to control IPC via COM Transparent COM Network user can communicate with RS232 COM device Alarm box Wireless alarm box protocol System can use COM to communicate with the wireless alarm box COM_GPS GPS module protocol You can connect to it to realize GPS function Function COM_RADAR Radar protocol Realize the radar speeding function and et...

Страница 27: ...ollowing sheet for detailed information Parameter Function Ethernet Please select the network card first Please select the port 02 if you are using wireless network and then set the wireless IP address Please note this function is for W series product only DHCP Dynamically get IP address You can get the device IP from the DHCP server if you enabled this function Device Name The device ID in the ne...

Страница 28: ...he domain name Max Connection Network user max amount The value ranges from 1 to 10 Network transmission QoS You can set the priority between fluency and video quality or self adaptive System can automatically adjust the bit stream or lower the resolution according to the network bandwidth Advanced Set The advanced set interface is shown as in Figure 3 16 Figure 3 16 Advanced Set Please refer to t...

Страница 29: ...device to get the setup activated z Device connects to the internet via PPPoE after reboot You can get the IP address in the WAN from the IP address column Email The email interface is shown as in Figure 3 17 Figure 3 17 Email Please refer to the following sheet for detailed information Parameter Function SMTP Server Input server address and then enable this function Port Default value is 25 You c...

Страница 30: ...unction and then set the corresponding interval System can send out the email regularly as you set here DDNS The DDNS interface is shown as in Figure 3 18 Figure 3 18 DDNS Please refer to the following sheet for detailed information You can refer to the Appendix for NO IP DDNS setup information Parameter Function Server Type You can select DDNS protocol from the dropdown list and then enable DDNS ...

Страница 31: ...an set interval value between the device and DDNS server here NAS NAS interface is shown as in Figure 3 19 Current series IPC does not support this function right now Figure 3 19 NAS Please refer to the following sheet for detailed information Parameter Function NAS enable Please select network storage protocol FTP and then enable NAS function Server IP Input remote storage server IP address Port ...

Страница 32: ...e button Refresh Click this button to get device latest configuration information NTP The NTP interface is shown as in Figure 3 20 Here you can realize network time synchronization Please enable current function and then input server IP port number time zone and time Figure 3 20 NTP Please refer to the following sheet for detail information Parameter Function Enable Enable NTP function or not Serv...

Страница 33: ...ed IP user can access the IPC See Figure 3 21 Please note you can not set white list and black list function at the same time Figure 3 21 IP Filter UNPN Go to the UPnP interface you can see an image is shown as in Figure 3 22 It allows you to establish the mapping relationship between the LAN and the public network Here you can also add modify or remove UPnP item ...

Страница 34: ...34 Figure 3 22 UNPN 3 2 6 Alarm Alarm setup interface is shown as in Figure 3 23 Figure 3 23 Alarm Setup ...

Страница 35: ... becomes activated in the specified periods z There are six periods in one day Please draw a circle to enable corresponding period z Select date If you do not select current setup applies to today only You can select all week column to apply to the whole week z Click OK button system goes back to alarm setup interface please click save button to exit Anti dither System only memorizes one event dur...

Страница 36: ...et PTZ movement when alarm occurs Such as go to preset x when there is an alarm z The PTZ configuration events include preset tour and pattern Capture You need to input capture channel number so that system can backu snapshot file to the SD card or send to the specified email box when alarm occurs Copy It is a shortcut menu button You can copy current channel setup to one or more all channels Save...

Страница 37: ... refer to the following sheet for detailed information Parameter Function Event Type There are three types Motion detection video loss Camera Masking Channel Select channel name from the dropdown list Enable You need to draw a circle to enable motion detection function ...

Страница 38: ...re is 1 channel alarm output z Corresponding to motion detection alarm output port z Enable alarm activation function You need to select alarm output port so that system can activate corresponding alarm device when alarm occurs Alarm latch System can delay the alarm output for specified time after alarm end The value ranges from 10s to 300s Record channel System auto activates motion detection cha...

Страница 39: ...ion Parameter Function Channel You can select monitor channel from the dropdown list Protocol Select the corresponding dome protocol such as PELCOD Address Set corresponding dome address Default value is 1 Please note your setup here shall comply with your dome address otherwise you can not control the speed dome Baud Rate Select the dome baud rate Default setup is 9600 Data Bit Default setup is 8...

Страница 40: ...ormation 3 2 9 Default Backup Default Restore factory default setup You can select corresponding items Backup Export current configuration to local PC or import configuration from current PC Please refer to Figure 3 28 Please note system can not restore some information such as network IP address Figure 3 28 Default and Backup Please refer to the following sheet for detailed information Parameter ...

Страница 41: ... to support current function Please select the storage device first and then you can see the items on your right become valid You can check the corresponding item here See Figure 3 29 Click the Execute the button system needs to reboot to activate current setup Figure 3 29 HDD Management Please refer to the following sheet for detailed information Parameter Function Format Clear data in the disk R...

Страница 42: ...arch alarm output status See Figure 3 30 Figure 3 30 Alarm I O Configuration Please refer to the following sheet for detailed information Parameter Function Alarm output There is only one output channel Please click the button 1 Trigger Enable disable alarm output device Refresh Search alarm output status 3 3 3 Record Record control interface is shown as in Figure 3 31 Please note current IPC seri...

Страница 43: ...bles auto record function as you set in record schedule setup Manual Enable corresponding channel to record no matter what period applied in the record setup Stop Stop current channel record no matter what period applied in the record setup 3 3 4 Account Here you can add remove user or modify password See Figure 3 32 ...

Страница 44: ...44 Figure 3 32 Account 3 3 5 Auto Maintenance Here you can select auto reboot and auto delete old files interval from the dropdown list See Figure 3 33 Figure 3 33 Auto Maintenance ...

Страница 45: ...nel Snapshot mode There are two modes Timing and activation Frame rate You can select from the dropdown list The value ranges from 1f s to 8f s Resolution You can select from the dropdown list The resolution may vary due to different series Quality You can select from the dropdown list Here is for you to set video quality 3 3 7 Abnormity The abnormity interface is shown as below See Figure 3 35 ...

Страница 46: ...46 Figure 3 35 Abnormity 1 IPC offline interface is shown as below See Figure 3 36 Figure 3 36 Abnormity 2 ...

Страница 47: ...d once alarm occurs For offline type only See Figure 3 36 Please note you need to go to chapter 3 3 3 record to set current period as auto record Record latch System can delay the record for specified time after alarm ended The value ranges from 10s to 300s Latch The alarm output can delay for the specified time after alarm stops The value ranges from 10s to 300s Send email If you enable this func...

Страница 48: ...oo Day Night Mode IPC day night mode switch There are three options color off color on auto Signal Standard Video input mode internal input BLC Backlight compensation level This series product does not support this function Scene Mode You can select the different scene mode such as auto sunny cloudy home office night disable and etc to adjust the video to the best quality Mirror It is to switch vi...

Страница 49: ...to gain and etc 3 4 2 Auto Register Auto register interface is shown as below See Figure 3 38 Figure 3 38 Auto Register Please refer to the following sheet for detailed information Parameter Function Enable Enable auto register function No Device management server number IP Device management server IP address Port Server port number Device ID Device ID in the device management server 3 4 3 Talk En...

Страница 50: ...50 Here you can set AMR audio compression bit rate It includes PCM G711a and G711u See Figure 3 39 Figure 3 39 Talk Encode ...

Страница 51: ...nel Then please click search button you can see the corresponding files in the list Select the file s you want to download and then click download button system pops up a dialogue box shown as in Figure 4 2 then you can specify file name and path to download the file s to your local pc Click Ok to complete the download procedure Figure 4 1 Search Main Interface ...

Страница 52: ...cord alarm record and motion detection record Alarm Search alarm record Motion Detection Search motion detection record Local Search local record Picture Search snapshot file Type Card This function is not available in current device Start time Set the file start time End time Set the file end time Item Channel Select the channel from the dropdown list ...

Страница 53: ...nload and the download becomes stop button There is a progress bar for your reference Open local record Select local record to play Operation Watermark Please note you need to go to chapter 3 2 2 Encode to enable watermark function first Click watermark button system pops up a dialogue box shown as in Figure 4 3 Default watermark character is DigitalCCTV Click local file you can select the recorde...

Страница 54: ...ms when disk is full Disk error System alarms when disk error occurs Camera masking System alarms when camera is viciously masking Encode alarm System alarms when encode module alarms Alarm Type External alarm Alarm input device sends out alarm Listening alarm System notifies web when alarm occurs you select from the above event type and then web can notify user Operation Video When alarm occurs s...

Страница 55: ... Type Parameter Function Prompt Automatically pops up alarm dialogue box Sound pop up System sends out alarm sound when alarm occurs You can specify as you wish Path Here you can specify alarm sound file ...

Страница 56: ...56 6 About Click about button you can view current web client information See Figure 6 1 Figure 6 1 ...

Страница 57: ...57 7 Log out Click log out button system goes back to log in interface See Figure 7 1 Figure 7 1 ...

Страница 58: ...There are five options No IP DynDNS CN99 Private and Oray y Server IP You can use ping command to get server s IP y Port input server port here y Domain Name Get the domain name you get from your DDNS service provider y User Get the user name you get from your DDNS service provider y Password Enter corresponding password Highlight the icon in front of Enable to enable the DDNS server configuration...

Страница 59: ...rom the server Then we have a constant domain name in the Web browser along with the HTTP port send a request to identify the car IP of the domain name typed The server will direct the domain name to the IP connection thus allowing access to the device which does not have a fixed IP in the network Note It is important to note that to gain access to the device in a local network it is necessary to ...

Страница 60: ... email containing username and password You can use this account to access the service 4 Open the e mail sent by trusted rmação No IP and double click the link that is below the phrase To activate your account please click the following URL in the body of the email See Figure 8 4 Figure 8 4 ...

Страница 61: ...ign and enter the email address and password you get earlier Click login to sign up you can see the welcome interface and configuration option of account See Figure 8 6 You can highlight manage host item Figure 8 6 7 The Manage Hosts interface is shown as in Figure 8 7 Click the Add Host button you can access the creation of a domain name ...

Страница 62: ...the name select the desired area This is your domain name for access to the device Click Create Host button at the bottom of the page Figure 8 8 9 Now you can see an interface is shown as in Figure 8 9 Here you can view domain name and the computer s current IP setup If you already have a domain name equal to gurado trusted you must define another name for the host ...

Страница 63: ...ompt Windows The server s IP will be displayed on the screen See Figure 8 10 Your device can use this IP to find the No IP server Figure 8 10 11 Please go to the device and access the MAIN MENU SETTING NETWORK DDNS Input server IP you get in the above step Select the DDNS Type as No IP DDNS and highlight the icon in front of Enable to enable the DDNS function Now fill the fields as described below...

Страница 64: ...vd16s480st no ip biz 2 If the device HTTP port is 80 just type the domain name Otherwise enter in the browser address as http nome the field created in Step 8 port number of HTTP For example http vd16s480st no ip biz 9090 3 Press Enter The system will ask install application webrec cab control or not Please click Yes to perform a successful connection 4 If the page does not appear on the computer ...

Страница 65: ...rence may be found in user interface z All the designs and software here are subject to change without prior written notice z If there is any uncertainty or controversy please refer to the final explanation of us z Please visit our website for more information ...

Отзывы: