135
Anti-dither: Here you can set anti-dither time. Here you can set anti-dither time. The
value ranges from 5 to 600s. The anti-dither time refers to the alarm signal lasts time.
It can be seem as the alarm signal activation stays such as the buzzer, tour, PTZ
activation, snapshot, channel record. The stay time here does not include the latch
time. During the alarm process, the alarm signal can begin an anti-dither time if
system detects the local alarm again. The screen prompt, alarm upload, email and etc
will not be activated. For example, if you set the anti-dither time as 10 second, you
can see the each activation may last 10s if the local alarm is activated. During the
process, if system detects another local alarm signal at the fifth second, the b uzzer,
tour, PTZ
activation, snapshot, record channel will begin another 10s while the
screen prompt, alarm upload, email will not be activated again. After 10s, if system
detects another alarm signal, it can generate an alarm since the anti-dither time is out.
Show message: System can pop up a message to alarm you in the local host screen if
you enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm
centre) if you enabled current function.
Send email: System can send out email to alert you when alarm occurs.
Record channel: you can select proper channel to record alarm video (Multiple
choices). At the same time you need to set alarm record in schedule interface (Main
Menu->Setting->Schedule) and select schedule record in manual record interface
(Main Menu->Advance->Manual Record).
Latch: Here is for you to set proper delay duration. Value ranges from 10 to 300
seconds. System automatically delays specified seconds in turning off alarm and
activated output after external alarm cancelled.
Tour: Here you can enable tour function when alarm occurs. System supports
1/8-window tour. Please note the tour setup here has higher priority than the tour
setup you set in the Display interface. Once there two tours are both enabled, system
can enable the alarm tour as you set here when an alarm occurred. If there is no
alarm, system implements the tour setup in the Display interface.
Snapshot: System can snapshot corresponding channel when an alarm occurs.
Please note the activation snapshot has the higher priority than schedule snapshot. If
you have enabled these two types at the same time, system can activate the
activation snapshot when alarm occurs, and otherwise system just operates the
schedule snapshot.
Video matrix: Check the box here to enable this function. When an alarm occurs,
SPOT OUT port displays device video output. It displays video (1-window tour) from
alarm activation channel you select at the Record channel item.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when alarm
occurs.
Please note, network alarm means the alarm signal from the TCP/IP. You can use
NET SDK to activate network alarm. Comparing with the local alarm, there is no type,
anti-dither, alarm upload function.
Please highlight icon
to select the corresponding function. After setting all the
Содержание HCVR5204A Series
Страница 1: ...Dahua HDCVI Standalone DVR User s Manual V1 5 0 ...
Страница 77: ...68 Figure 3 10 Figure 3 11 Figure 3 12 Figure 3 13 Figure 3 14 485 Port 485 Port 485 Port 485 Port 485 Port ...
Страница 78: ...69 3 8 Other Interfaces There are still other interfaces on the DVR such as USB ports ...
Страница 139: ...130 Figure 4 74 Figure 4 75 ...
Страница 140: ...131 Figure 4 76 Figure 4 77 ...
Страница 145: ...136 setups please click save button system goes back to the previous menu Figure 4 81 Figure 4 82 ...
Страница 146: ...137 Figure 4 83 Figure 4 84 ...
Страница 148: ...139 Figure 4 86 Figure 4 87 ...
Страница 156: ...147 Figure 4 99 Figure 4 100 ...
Страница 217: ...208 Figure 5 61 Figure 5 62 ...
Страница 248: ...239 Please check and maintain the device regularly ...
Страница 266: ...257 ...