Alarm Control Panel Installer Manual
71
DIGITAL FORMAT
1.39
After entering the Installer Menu, press
and
to scroll up and down until you reach the
Step 1
DIGITAL FORMAT menu. See Figure 1-39.
Digital format
Figure 1-39
Press
to enter the programming mode.
Step 2
Configure the programming settings. See Table 1-35.
Step 3
Take Event No.001 as an example. See Figure 1-40.
Periodic test
Figure 1-40
T
represents telephone number. To select which telephone number to be linked, on this interface,
press
, the telephone number linkage setting interface is shown. See Figure 1-41.
PSTN TEL1, PSTN TEL2, PSTN TEL3: Three telephone numbers mentioned in Monitor
Station menu.
TRUE: Links this telephone number
FALSE: Does not link this telephone number.
Telephone number linkage
Figure 1-41
Table 1-35 Digital format setting
Category
Event No.
Setting
CID Code
System report
code group
001
Periodic Test
602
002
Reserved
Reserved
003
AC Loss
301
004
Low System Battery
302
005
System Battery Failure
309
006
Telephone Line Failure
351
007
No GSM Field
352
008
System Tamper
137
009
Siren Tamper
137
010
Reserved
Reserved