Alarm Control Panel Installer Manual
38
Submenu
Setting
commands or direct auxiliary signals.
Press
to return to the WIRED ZONES menu.
Step 5
Then you can continue with programming other wired zones, or press
to return to the
WIRED ZONES menu from where you can press
and
to move to the next menu or press
to exit from the Installer Menu.
Key Type Zone
The key type zone is used as an auxiliary command to arm/disarm one or more areas. In the area screen,
the areas that the key zone will attempt to arm/disarm are defined. Having defined the Areas on which it will
be able to act, the FUNCTION parameter is proposed, which provides options as below:
ON/OFF
Modality: Select ON/OFF option, the key zone is used as an ON and OFF command. The type of
arming will then be selected from TOTAL, PARTITION 1, PARTITION 2, and PARTITION 1+2.
Trigger: Select IMPULSE or BISTABLE (only for the ON/OFF command). This choice determines
whether the key zone acts with an IMPULSE or BISTABLE command (on each N.C. to N.O.
change and vice versa).
Arming: Select DELAYED OR IMMEDIATE.
With delayed arming, the output time programmed for the Area on the AREAS menu will then
follow. With immediate arming, the output time will not be taken into account and it will be
executed immediately.
FORCED ARM: Select YES or NO.
If YES is selected, the key Zone will be armed even though there are open Zones. If NO is
selected, the arming will take place only if all the Area Zones are ready for arming.
Link: Set link output associated with the input.
ON ONLY, OFF ONLY
The settings ON ONLY and OFF ONLY use the IMPULSE type only.
Modality: Select ON/OFF option, the key zone is used as an ON and OFF command. The type of
arming will then be selected from TOTAL, PARTITION 1, PARTITION 2, and PARTITION 1+2.
Arming: Select DELAYED OR IMMEDIATE.
With delayed arming, the output time programmed for the Area on the AREAS menu will then
follow. With immediate arming, the output time will not be taken into account and it will be
executed immediately.
FORCED ARM: Select YES or NO.
If YES is selected, the key Zone will be armed even though there are open Zones. If NO is
selected, the arming will take place only if all the Area Zones are ready for arming.
Link: Set link output associated with the input.
SPECIAL
If the SPECIAL option is selected, two submenus are proposed.
Содержание DHI-ARC3008C
Страница 1: ...Alarm Control Panel Installer Manual V1 0 1 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...
Страница 16: ...Alarm Control Panel Installer Manual 15 Wiring of detectors Figure 1 6 ...
Страница 17: ...Alarm Control Panel Installer Manual 16 Keypad connection Figure 1 7 ...
Страница 67: ...Alarm Control Panel Installer Manual 66 Vocal message flow Figure 1 36 ...