The manual helps you to use our product properly. To avoid danger and property damage, read the 
manual carefully before using the product, and we highly recommend you to keep the manual well 
for future reference. 

Operating Requirements 

  Transport, use, and store the device in allowed humidity and temperature ranges. 

  Avoid liquids splashing on the device. Do not place objects full of liquid on the device to avoid 

liquid flowing into the device. 

  Do not disassemble the device without professional instruction. 

  Use the device at rated input and output voltage. 

  Make sure that the power supply of the device works properly before use. 

  Do not pull out the power cable of the device while it is powered on. 

  When removing the cable, power off the device first to avoid personal injury. 

  Operating temperature range: –30 °C (-22 °F) to +65 °C (+149 °F). 

  This is a class A product. In a domestic environment this may cause radio interference in which 

case the user may be required to take adequate measures. 

Installation Requirements 

  Observe all safety procedures and wear required protective equipment provided for your use 

while working at height. 

  Use the battery properly to avoid fire, explosions, and other dangers. 

  Do not expose the device directly to sunlight, and keep it away from heat. 

  Do not install the device in a damp environment, and keep it away from dust and soot. 

  Install the device in a well-ventilated environment. Do not block the vent of the device. 

  Strictly abide by local electrical safety standards, and make sure that the voltage in the area is 

steady and conforms to power requirements of the device. 

  Use the power adapter or case power supply provided by the device manufacturer. 

  Connect the device with the adapter before power on. 

  Do not connect the device to more than one power supply. Otherwise, the device might be 

damaged. 

  The device is a class I electrical appliance. Make sure that the power supply of the device is 

connected to a power socket with protective earthing. 

  Be sure to ground the device (cross section of copper wire: > 2.5 mm²; resistance to ground: ≤ 4 

Ω). 

  Voltage stabilizers and lightning protection devices are optional according to the power supply 

and surrounding environment. 

  To ensure heat dissipation, the gap between the device and the surrounding area should not be 

less than 10 cm on the sides and 10 cm on top of the device. 

  When installing the device, make sure that the power plug and appliance coupler can be easily 

reached to cut off power. 

  Do not block the ventilator of the device with objects, such as newspaper, table cloth or curtains. 

  Do not put open flames, such as a lit candle, on the device. 

Содержание DH-PFS3110-8ET-96

Страница 1: ...Ethernet Switch 4 8 port Unmanaged Hardened Switch Quick Start Guide V1 0 2...

Страница 2: ...ance description August 2023 V1 0 1 Updated Important Safeguards and Warnings Updated 1 1 Introduction Updated 1 2 Features Updated 2 1 Front Panel added Figure 2 2 Updated 2 2 Side Panel added Figure...

Страница 3: ...manual Please contact customer service for the latest program and supplementary documentation There might be errors in the print or deviations in the description of the functions operations and techn...

Страница 4: ...ers Do not expose the device directly to sunlight and keep it away from heat Do not install the device in a damp environment and keep it away from dust and soot Install the device in a well ventilated...

Страница 5: ...IV Maintenance Requirements Power off the device before maintenance Mark key components on the maintenance circuit diagram with warning signs...

Страница 6: ...1 1 2 Features 1 2 Port and Indicator 2 2 1 Front Panel 2 2 2 Side Panel 3 3 Installation 5 4 Wiring 6 4 1 Connecting GND 6 4 2 Connecting Power Cord 6 4 3 Connecting SFP Ethernet Port 7 4 4 Connecti...

Страница 7: ...100 Mbps or 10 Mbps 100 Mbps 1000 Mbps Ethernet ports Uplink ports include Ethernet ports and optical ports All ports meet the requirements of IEEE802 3af and IEEE802 3at standards The red ports also...

Страница 8: ...ith PoE Figure 2 2 Front panel without PoE Following are all the ports and indicators on the front panel of the 4 8 port unmanaged hardened switch The actual device might only have some of these ports...

Страница 9: ...ing data 10 Mbps 100 Mbps 1000 Mbps Off No data transmission 8 PoE Ethernet ports status indicator On Powered by PoE Off Not powered by PoE 9 Single port connection or data transmission status indicat...

Страница 10: ...transmission speed to 10 Mbps In Extend Mode the transmission distance of the PoE port is up to 250 m but the transmission rate drops to 10 Mbps The actual transmission distance might vary due to pow...

Страница 11: ...upports DIN rail mount Hang the switch hook on the rail and press the switch to make the buckle latch on to the rail The width of the guide rail supported by the device is 50 mm Figure 3 1 DIN rail No...

Страница 12: ...the GND resistance must be less than 4 4 2 Connecting Power Cord Models with PoE support two power inputs PWR1 and PWR2 You can select a backup power supply to ensure power is continuously provided ev...

Страница 13: ...es before installing the SFP module and wearing an antistatic wrist and confirm that the antistatic wrist is securely linked to the surface of the gloves Step 1 Lift the handle of SFP module verticall...

Страница 14: ...can be automatically configured to full duplex half duplex operation mode It supports MDI MDI X self recognition of the cable therefore you can use a cross over cable or straight through cable to conn...

Страница 15: ...ct the terminal device PoE Ethernet port to the switch PoE Ethernet port through the network cable to achieve synchronized network connection and power supply The maximum distance between the switch a...

Страница 16: ...example place the device in a special computer room and cabinet and implement well done access control permission and key management to prevent unauthorized personnel from carrying out physical contac...

Страница 17: ...smission efficiency 12 Secure Auditing Check online users we suggest that you check online users regularly to see if the device is logged in without authorization Check device log By viewing the logs...

Отзывы: