Quick Start Guide
2
Port
Port Name
Description
ALARM_IN
Receives the switch signal of external alarm source.
ALARM_GND
Ground connection.
1.2 Connecting Alarm Input/Output
The camera can connect to external alarm input/output device through digital input/output port.
Alarm input/output is available on select models.
Step 1 Connect alarm input device to the alarm input end of the I/O port. See Figure 1-2.
Device collects different states of alarm input port when the input signal is idling and
being grounded.
● Device collects logic "1" when input signal is connected to +3V to +5V or idling.
● Device collects logic "0" when input signal is grounded.
Figure 1-2 Alarm input
Step 2 Connect alarm output device to the alarm output end of the I/O port. The alarm output
is open-drain output, which works in the following modes.
● Mode A: Level application. Alarm outputs high and low level, and the alarm outlet
is OD, which requires external pull-up resistance (10K Ohm typical) to work. The
maximum external pull-up level is 12V, maximum port current is 300mA and the
default output signal is high-level (external pull-up voltage). The default output
signal switches to low- level when there is alarm output (As long as the operating
current is below 300mA, the output low-level voltage is lower than 0.8V).
● Mode B: Switch application. Alarm output is used to drive external circuit, the
maximum voltage is 12V and the maximum current is 300mA. If the voltage is
higher than 12V, please use an additional electric relay.
Figure 1-3 Mode A
Step 3 Log in to web interface, and configure alarm input and alarm output in alarm setting.