Modifying alarm linkage parameter
Figure 4-9
Table 4-2 Alarm linkage parameter description
Parameter
Description
Alarm Input
You cannot modify the value. Keep it default.
Name
Enter a zone name.
Alarm Input Type
There are two options:
NO
and
NC
.
If alarm input type of the alarm device you purchased is
NO
, then you
should select
NO
; otherwise you should select
NC
.
Fire Link Enable
If fire link is enabled, the standalone will output alarms when fire
alarms are triggered. The alarm details will be displayed in the alarm
log.
Alarm output and access link are NO by default if fire link is enabled.
Alarm Output
Enable
The relay can output alarm information (will be sent to the
management platform) if the
Alarm Output
is enabled.
Duration (Sec.)
The alarm duration, and the range is 1–300 seconds.
Alarm Output
Channel
You can select an alarm output channel according to the alarming
device that you have installed. Each alarm device can be regarded as
a channel.
Access Link
Enable
After the Access Link is enabled, the standalone will be normally open
or normally closed when there are input alarm signals.
Channel Type
There are two options:
NO
and
NC
.
Click
OK
, and then the configuration is completed.
Step 3
Содержание Access Standalone
Страница 1: ...Access Standalone User s Manual V1 0 1...
Страница 55: ...47 The homepage of the web is displayed...
Страница 57: ...49 Homepage Figure 6 2 On the homepage click Device Step 4 Device Figure 6 3 Click Add Step 5...
Страница 64: ...56 Authentication Figure 6 12 Click Edit and then click in Card section Step 2...
Страница 65: ...57 Editing Figure 6 13 Select the card reader of the access standalone as needed Step 3...
Страница 71: ...63 User group manager Figure 6 19 2 Click Add...