background image

 

 

Operation and Daily Maintenance  

 

Do not touch the heat dissipation component of the unit. This part of the unit is hot and may 

cause a burn.  

 

Do not open or dismantle the device; there are no components that a user can fix or replace. 

Opening the unit may cause water leakage or expose components to direct light. Contact the 

manufacturer or a qualified service representative to service the camera or to replace a 

component, including the desiccant. 

 

Dahua recommends the use of a thunder-proof device in concert with the unit. 

 

Do not touch the CCD or the CMOS optic sensor. Use a blower to clean dust or dirt on the lens 

surface. Use a dry cloth dampened with alcohol and gently wipe away any dust on the lens.  

 

Use a dry soft cloth to clean the unit’s housing. If the unit is particularly dusty, use water to dilute 

a mild detergent, apply the diluted detergent to a soft cloth, then gently clean the device. Finally, 

use a dry cloth to wipe the unit dry. Do not use a volatile solvent like alcohol, benzene, or thinner; 

or use a strong detergent with abrasives, which may damage the surface coating or reduce the 

working performance of the unit. 

 

Do not touch or wipe a dome cover during installation, this cover is an optical device. Refer to 

the following methods clean the dome cover:  

  Stained with dirt: Use an oil-free soft brush or blower to gently remove the dirt. 

  Stained with grease or fingerprints: Use a soft cloth to wipe gently the water droplet or the oil 

from the dome cover. Then, use an oil-free cotton cloth or paper soaked with alcohol or 

detergent to clean the lens from the center of the dome to outside. Change the cloth several 

times to ensure the dome cover is clean. 

Lifting Appliance Requirement  

 

Select the proper PTZ dome installation mode and use the proper lifting device to safely lift the 

camera at the installation site. 

 

Ensure that the lifting device has the proper capacity to reach the installation height. 

 

Use the lifting device in accordance with its operating instructions and abide by the device’s 

safety precautions. 

Warnings 

 

Change the default password after the initial login to protect the integrity of the network. 

 

Use the standard accessories provided by the manufacturer and ensure the unit is installed and 

commissioned by qualified professionals.  

 

Protect the lens area from laser radiation when using a laser device to aid in installation and 

leveling of the unit. 

 

Do not supply power via the Ethernet connection (PoE) when power is already supplied via the 

power connector.  

Содержание 59230IC

Страница 1: ...4 MP HDCVI PTZ Network Camera 59430IC 59230IC Quick Start Guide Version 001 001 Dahua Technology USA Inc ...

Страница 2: ...al Notices 4 Copyright 4 Trademarks 4 1 4 Disclaimer 5 2 Unpacking 6 2 1 Parts List 6 2 2 User supplied Tools and Hardware 6 3 Installation and Configuration 7 3 1 Framework and Dimensions 7 3 2 Wiring 8 3 3 Alarm Setup 8 Alarm Input 8 Alarm Output Level Application 9 Alarm Output Switch Application 9 4 Device Installation 10 4 1 Cable Requirements 11 4 2 Preparing the Camera 11 Unpacking the Came...

Страница 3: ...o protect the unit from damage especially in damp environments Protect the plug and power cord from foot traffic being pinched and its exit from the unit Units with or without an ON OFF switch have power supplied to the unit whenever the power cord is inserted into the power source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power di...

Страница 4: ...ing or installation Environmental Precautions Do not aim the unit at a strong light source or into direct sunlight to focus A strong light source may cause overexposure and may affect the longevity of the CCD or the CMOS sensor Transport use and store the unit within the specified temperature and humidity range Do not place the unit in a wet dusty extremely hot or an extremely cold environment and...

Страница 5: ...r wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove the dirt Stained with grease or fingerprints Use a soft cloth to wipe gently the water droplet or the oil from the dome cover Then use an oil free cotton cloth or paper soaked with alcohol or detergent to...

Страница 6: ...tee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Страница 7: ...ry information Dahua accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between this guide and the product described Dahua is not liable for any loss caused by installation operation or maintenance inconsistent with the information in this guide Video loss is inherent to all digital surveillance and recording devices therefore Dahua cannot ...

Страница 8: ...o transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please refer to the enclosed CD for more details to view the detailed User s Manual and for configuration software 2 1 Parts List Package Item Quantity HDCVI PTZ Camera 1 AC24V 3A Power Supply 1 PFB300S Wall Mount 1 PFA110 Mount Adapter 1 Roll of Teflon Tape 1 PTZ Manu...

Страница 9: ... Installation and Configuration 3 1 Framework and Dimensions The following figures show the dimensions of the device in mm in These images are intended as a reference only Figure 3 1 Dimensions for 59430IC ...

Страница 10: ...ND RS485 Yellow RS485 A Orange RS485 B 3 3 Alarm Setup Certain devices support alarm inputs and outputs check your specific device for alarm capability Alarm Input Refer to Figure 3 3 for alarm input configuration The device collects that status of the alarm input port when the input signal is idle or grounded If the input signal is connected to the 3 3 V or it is idle then the device receives the...

Страница 11: ... external pull up level is 5 V and the maximum port current is 5 mA Once the output increases the pull up resistance the alarm decreases the output voltage to the normal state low level at less than 0 8 V Figure 3 3 Alarm Output Switch Application The alarm output drives the external circuit with a maximum current of 30 mA and a maximum voltage of 5 V It is recommended to add a relay if the circui...

Страница 12: ...ide a different permanently earthed metal conduits not supplied Warning Install external interconnecting cables in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I CSA C22 1 for CAN application and in accordance to local country codes for all other countries Branch circuit protection incorporating a 20 A 2 pole Listed Circuit Breaker or Branch Rated Fuses are re...

Страница 13: ... balun required 720p 380 m 1246 72 ft 1080p 380 m 1246 72 ft 4 MP 200 m 656 17 ft 4 2 Preparing the Camera The HDCVI PTZ camera comes with the PFB300S Wall Mount and the PFA110 Mount Adapter the installer must supply the following hardware Four 4 bolts washers or other fastening hardware to secure the wall mount to the installation medium The hardware must be capable of supporting eight 8 times th...

Страница 14: ...rimeter mounting holes 2 Pre drill the four perimeter holes as marked on the wall for the expansion bolts using a drill bit that is no wider than the expansion bolt 3 Drill a 50 mm approximately 2 in center hole to route the cables if necessary 4 Insert an expansion bolt into each pre drilled perimeter hole if necessary 5 Wrap several turns of Teflon tape around the threads on the PFA110 Mount Ada...

Страница 15: ...he external enclosure to the inside hole of the adapter block and then push it to the end and then tighten the three M6 screws on the adapter block firmly Note Ensure the M6 screws are tightly fixed to secure the dome to the wall mount 10 Make the proper wiring connections and supply power to the camera Refer to Section 3 2 Wiring Note The video connection is covered by a heat shrink tube Once the...

Страница 16: ...ology USA Inc 23 Hubble Irvine CA 92618 Tel 949 679 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change without notice ...

Отзывы: