1  Welcome 

This manual offers reference material and general information about the basic operation, 

maintenance, and troubleshooting of the Dahua Multi-Sensor Panoramic Camera. Read, follow, and 

retain the following safety instructions. Heed all warning on the unit and in the operating instructions 

before operating the unit. Keep this guide for future reference. 

1.1  Important Safeguards and Warnings  

Electrical safety 

 

Install the unit in accordance with the manufacturer’s instructions and in accordance with 

applicable local codes.  

 

All installation and operation must conform to your local electrical safety codes.  

 

Do not overload outlets and extension cords, which may cause fire or electrical shock. 

 

Do not place the camera near or in a place where the camera may contact overhead power lines, 

power circuits, or electrical lights. 

 

Ensure power conforms to SELV (Safety Extra Low Voltage) and that the limited power source is 

rated AC 24V as specified in IEC60950-1. (Power supply requirement is subject to the device 

label). 

 

All input/output ports are SELV circuits. Ensure that SELV circuits are connected only to other 

SELV circuits.  

 

Ground the unit using the ground connection of the power supply to protect the unit from damage, 

especially in damp environments. 

 

Protect the plug and power cord from foot traffic, being pinched, and its exit from the unit. 

 

Units with or without an ON/OFF switch have power supplied to the unit whenever the power 

cord is inserted into the power source; however, the unit is operational only when the ON/OFF 

switch is in the ON position. The power cord is the main power disconnect device for switching 

off the voltage for all units.  

 

Operate the unit only from the type of power source indicated on the label. Before proceeding, 

disconnect the power from the cable to be installed into the unit.  

  For external power supplied units, use only the recommended or approved power supplies. 

  Limited power sources must comply with EN 60950. Substitutions may damage the unit or 

cause fire or shock. 

  For 24 VAC units, voltage applied to the unit’s input power should not exceed ±25%. User-

supplied wiring must comply with local codes (Class 2 power levels). Do not ground the 

supply at the terminals or at the unit’s power supply terminal.  

  Contact the local dealer or the power company to verify the correct power supply.  

 

Do not supply power via the Ethernet connection (PoE) when power is already supplied via the 

power connector.  

 

Do not attempt to service the unit. Opening or removing covers may expose you to dangerous 

voltage or other hazards. Refer all servicing to qualified personnel. 

Содержание 59230IC

Страница 1: ...4 MP HDCVI PTZ Network Camera 59430IC 59230IC Quick Start Guide Version 001 001 Dahua Technology USA Inc ...

Страница 2: ...al Notices 4 Copyright 4 Trademarks 4 1 4 Disclaimer 5 2 Unpacking 6 2 1 Parts List 6 2 2 User supplied Tools and Hardware 6 3 Installation and Configuration 7 3 1 Framework and Dimensions 7 3 2 Wiring 8 3 3 Alarm Setup 8 Alarm Input 8 Alarm Output Level Application 9 Alarm Output Switch Application 9 4 Device Installation 10 4 1 Cable Requirements 11 4 2 Preparing the Camera 11 Unpacking the Came...

Страница 3: ...o protect the unit from damage especially in damp environments Protect the plug and power cord from foot traffic being pinched and its exit from the unit Units with or without an ON OFF switch have power supplied to the unit whenever the power cord is inserted into the power source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power di...

Страница 4: ...ing or installation Environmental Precautions Do not aim the unit at a strong light source or into direct sunlight to focus A strong light source may cause overexposure and may affect the longevity of the CCD or the CMOS sensor Transport use and store the unit within the specified temperature and humidity range Do not place the unit in a wet dusty extremely hot or an extremely cold environment and...

Страница 5: ...r wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove the dirt Stained with grease or fingerprints Use a soft cloth to wipe gently the water droplet or the oil from the dome cover Then use an oil free cotton cloth or paper soaked with alcohol or detergent to...

Страница 6: ...tee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Страница 7: ...ry information Dahua accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between this guide and the product described Dahua is not liable for any loss caused by installation operation or maintenance inconsistent with the information in this guide Video loss is inherent to all digital surveillance and recording devices therefore Dahua cannot ...

Страница 8: ...o transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please refer to the enclosed CD for more details to view the detailed User s Manual and for configuration software 2 1 Parts List Package Item Quantity HDCVI PTZ Camera 1 AC24V 3A Power Supply 1 PFB300S Wall Mount 1 PFA110 Mount Adapter 1 Roll of Teflon Tape 1 PTZ Manu...

Страница 9: ... Installation and Configuration 3 1 Framework and Dimensions The following figures show the dimensions of the device in mm in These images are intended as a reference only Figure 3 1 Dimensions for 59430IC ...

Страница 10: ...ND RS485 Yellow RS485 A Orange RS485 B 3 3 Alarm Setup Certain devices support alarm inputs and outputs check your specific device for alarm capability Alarm Input Refer to Figure 3 3 for alarm input configuration The device collects that status of the alarm input port when the input signal is idle or grounded If the input signal is connected to the 3 3 V or it is idle then the device receives the...

Страница 11: ... external pull up level is 5 V and the maximum port current is 5 mA Once the output increases the pull up resistance the alarm decreases the output voltage to the normal state low level at less than 0 8 V Figure 3 3 Alarm Output Switch Application The alarm output drives the external circuit with a maximum current of 30 mA and a maximum voltage of 5 V It is recommended to add a relay if the circui...

Страница 12: ...ide a different permanently earthed metal conduits not supplied Warning Install external interconnecting cables in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I CSA C22 1 for CAN application and in accordance to local country codes for all other countries Branch circuit protection incorporating a 20 A 2 pole Listed Circuit Breaker or Branch Rated Fuses are re...

Страница 13: ... balun required 720p 380 m 1246 72 ft 1080p 380 m 1246 72 ft 4 MP 200 m 656 17 ft 4 2 Preparing the Camera The HDCVI PTZ camera comes with the PFB300S Wall Mount and the PFA110 Mount Adapter the installer must supply the following hardware Four 4 bolts washers or other fastening hardware to secure the wall mount to the installation medium The hardware must be capable of supporting eight 8 times th...

Страница 14: ...rimeter mounting holes 2 Pre drill the four perimeter holes as marked on the wall for the expansion bolts using a drill bit that is no wider than the expansion bolt 3 Drill a 50 mm approximately 2 in center hole to route the cables if necessary 4 Insert an expansion bolt into each pre drilled perimeter hole if necessary 5 Wrap several turns of Teflon tape around the threads on the PFA110 Mount Ada...

Страница 15: ...he external enclosure to the inside hole of the adapter block and then push it to the end and then tighten the three M6 screws on the adapter block firmly Note Ensure the M6 screws are tightly fixed to secure the dome to the wall mount 10 Make the proper wiring connections and supply power to the camera Refer to Section 3 2 Wiring Note The video connection is covered by a heat shrink tube Once the...

Страница 16: ...ology USA Inc 23 Hubble Irvine CA 92618 Tel 949 679 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change without notice ...