Quick Start Guide
4
Electric Specification
1.5
Table 1-2
Electric specification
Parameter
Description
Input voltage
12 VDC
Maximum current
≤ 0.7 A
Power consumption
≤ 8.4 W
Electrical connection Power, Ethernet, audio ports, alarm and RS-485 port on the control cable
by default.
Power Standard
Make sure that the power supply is correct before operating the device. Strictly follow the local
electrical safety standards.
Strictly follow the power supply requirements of the device.
Use the power adapter of a regular brand with UL, CE\FCC and other related certifications
passed.
Input the rated voltage 12 VDC (
±
10% voltage) and input the rated current 2A power
adapter to supply power to the device.
Provide stable long-time power supply.
The power adapter provided with the Camera is recommended.
If power adapter does not come with the Camera, select a power source that complies with
IEC62368-1/IEC60950-1. IEC62368-1 requires compliance with ES1 (Electrical Energy Source
Class 1) and PS1/PS2 (Power Source Class 1 or 2) classification standards and Limited Power
Source Standards. IEC60950-1 requires compliance with SELV (Safety Extra-low Voltage
Circuit) and Limited Power Source standards.
Install cables with easy-to-use circuit breaker, which is for emergent power off when necessary.
Do not tread or put pressure on the power cable, especially the plug, the outlet and the
connection point where the cable comes out.
Environment Requirements
1.6
Table 1-3
Environment requirements
Parameter
Description
Air pressure
80 kPa–110 kPa
Operating
temperature
T5/T100 °C: –40 °C to +60°C; T6/T80°C: –40 °C to +55 °C
Operating humidity
≤ 85% (RH)
Special conditions of use:
1.
End user shall comply with the manufacture’s User manual to minimize the risk from electrostatic
discharge: Conductors and live parts are prohibited from contacting the non-metallic enclosure
during normal operation of the equipment
.
Use insulators to contact non-metallic enclosures
during maintenance.
2.
Tamb1: -40°C to +60°C.
Tamb2: -40°C to +55°C.