The Dagan IX2-700 Dual Intracellular Preamplifier is warranted to be free from 
defects in construction caused by materials and workmanship for a period of one 
year from the date of purchase. During this period, Dagan Corporation will service 
your instrument at no charge. 

 

We prefer that any MAJOR service work that might become necessary be 
performed in our laboratory. However, you may be able to service your own 
instrument if you desire in certain situations. There are a few MINOR problems 
that you may correct yourself and not void the warranty. These include changing 
the fuses and replacing defective printed cards: 

 

MINOR REPAIRS 

 

For safety, always be sure to disconnect the line power to the 
instrument before working inside the cabinet. 

 

MAIN FRAME COVER REMOVAL 

 

Remove the four screws on the top cover and slide it backwards. 

 

PRINTED C1RCU1T CARD REMOVAL 

 

Unscrew the desired PC board locking screws. Unsnap the connectors and

 

pull them upwards. 

 

FUSE REPLACEMENT 

 

The IX2-700 has a fused power supply. The fuse is located inside the 
cabinet on the rear panel printed circuit board. It is easily snapped out for 
inspection if the power switch pilot light should fail to function. It is a slow-
blow 1 amp. 250 volt 3AG type. 

 

A phone call to us can usually provide enough data to confirm the problem. We 
will immediately ship to you the replacement parts that are necessary to fix the 
instrument. If your problem is more serious, or if you prefer that we replace any 
faulty cards, please call us first. We will issue you a return authorization number. 
You must put this return number on the outside of the box and on the packing slip 
or instruction sheet accompanying the instrument. We will immediately repair all 
instruments that are accompanied by an authorization number and return them to 
you. 

Содержание IX2-700

Страница 1: ...nual Version 1 1 Dagan Corporation 2855 Park Avenue Minneapolis MN 55407 USA 612 827 5959 Fax 612 827 6535 Email info dagan com Web www DAGAN com Warning This instrument is not designed or intended fo...

Страница 2: ...0 Dual Intracellular Preamplifier 1 TABLE OF CONTENTS Page IX2 700 Block Diagram 2 Introduction and Features 3 Control Description 4 Operation 7 Specifications 11 Accessories 12 Warranty Services Repa...

Страница 3: ...IX2 700 Dual Intracellular Preamplifier 2...

Страница 4: ...ltering electrode impedance testing and a back lighted for dark labs LCD voltage and current meter FEATURES Small Box Probe in five current ranges with automatic decimal point selector on current mete...

Страница 5: ...initiating buzzes until you achieve desired cell penetration Buzz magnitude is a trimpot located under the buzz switch CAPACITANCE COMPENSATION CONTROL This control provides input capacitance neutrali...

Страница 6: ...current is 100 nA full scale times the headstage multiplier Thus the X 1 headstage would change the full scale dial reading to 9 99 nA The current control is linear and the readout corresponds to the...

Страница 7: ...able In addition the Buzz Switch is many times useful for clearing a blocked microelectrode and impaling cells MONITOR MON BNC CONNECTOR Actual currents being passed through the microelectrode are mon...

Страница 8: ...hat the voltage is at ground potential ground voltage trace adjust position on oscilloscope to desired position uncouple voltage channel and return trace to the same position using the DC offset contr...

Страница 9: ...when you switch polarity the bridge is balanced The main disadvantage with a bridge circuit arises from changes in the microelectrode resistance The circuit works on the assumption that the bridge is...

Страница 10: ...scillating IMPALING THE CELL With the system calibrated the electrode in good condition and the amplifier compensated you are ready to penetrate the cell As the barrel of the electrode enters the tiss...

Страница 11: ...from channels 1 and 2 are equal Should you need to adjust the trimpot contact the factory for explicit instructions The Cx control is for cross capacitance nulling to adjust for variations in dynamic...

Страница 12: ...pf 1010 M 1 1 A 10M 50 v 10kHz 10M 2 to 50 M 10 pf 35 pf 1011 M 1 Standard 100nA 100M 50 v 1kHz 100M 20 to 500 M 10 pf 35 pf 1012 M 01 10nA 1G 40 v 100Hz 1G 200 to 5000 M 20 pf 1013 M 001 1nA 10G 35 v...

Страница 13: ...1999 my meter displays channel 1 and 2 voltage and current and channel 1 minus 2 voltage decimal point is automatically set Cross Capacitance Control Cx For ion selective electrode balancing Size 3 1...

Страница 14: ...the four screws on the top cover and slide it backwards PRINTED C1RCU1T CARD REMOVAL Unscrew the desired PC board locking screws Unsnap the connectors and pull them upwards FUSE REPLACEMENT The IX2 7...

Отзывы: