DNPB328 Operation Manual
5) Test the tool stroke. If the stroke is still not what it should be, some air could have entered
the
oil cylinder (#15)
while refilling the oil in the tool.
To release this extra air from the tool, connect the tool to the air supply, pull the tool
trigger
(#53)
6 or 7 times, then loosen the
screw (#9)
, to let the extra air leak out and then tighten
the
screw (#17)
again.
OPTIONAL USE OF AIR FLOW ADJUSTOR
The
air flow adjustor (in the tool accessories pack)
allows you to adjust the air flow released
from the tool when the tool is operated. It has no effect on the performance of the tool itself but
is used based on the tool operator’s personal preference.
The operator may feel uncomfortable with the air released from the tool blowing on his / her arm.
Once mounted on the back of the
compressed spring pedestal (#21),
this device allows the
operator to direct the air release away from their body, while still providing access to the button
at the back of the
compressed spring pedestal (#21) -
via the window in the
air flow adjustor
-
to release the tool from a set rivnut when necessary (refer to
TOOL OPERATION FOR SETTING
RIVNUT section 3
).
All manuals and user guides at all-guides.com