26
4-1. Testing Mode
PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process
Press power button → Press "SPIN" button
3 times with pressing "WASH" button. → Press Water Temp button, choose the mode (ref.below)
4. TEST MODE
Program Ver.
Display on LED
REMARK
① MAIN Program Ver. Ⅰ
: Dry, Nation, Program Ver.
② MAIN Program Ver. Ⅱ
: V, Spin RPM, Panel, Capacity
→ ①, ② are displayed alternately.
Ref.below table
Display on LED
① FRONT Program Ver.
② MOTOR Program Ver.
→ ①, ② are displayed alternately.
LC
Lock Close
H
HOT VALVE
C
COLD VALVE
P
PRE VALVE
bb
BUBBLE
dr
Drain Pump
CP
CIRCLE PUMP
d
DRY VALVE
--
Pause
r
Motor operate to right side.
--
Pause
L
Motor operate to left side.
--
Pause
F
Fan motor
run
Operate time
After checking, display
b1,b5 on UNI model
b1
Fail to operate
only for DD
b2
Over load.
only for DD
b3
Hall sensor error.
only for DD
b4
Motor don't set.
only for DD
b5
RPM set fail .
only for DD
b6
Over current on motor.
only for DD
b7
OP AMP abnomal voltage.
only for DD
b8
IPM fault signal check.
only for DD
b9
High volatage.
only for DD
bA'
low volatage.
bb
connect signal error.
LO
Lock open.