![Daewoo WFC0A2 Series Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/daewoo/wfc0a2-series/wfc0a2-series_service-manual_499290024.webp)
23
2-3. Drying Sequence
1) Consist of drying sequence.
ex) select normal drying (Total spend time 4:08)
3) Drying V/V working
① It works from the after 20sec, 10 seconds On / 10 seconds Off operates drying cycle to the end.
② DRAIN PUMP operate 10 sec On / 30 sec off at the end of a cycle COOLING.
4) COOLING
① Fan motor and Main motor work at once during Cooling Sequence to low temperature.
② Temp. of Drum is less than 55°C or Cooling Sequence times is 20 min.
(for saftety, operate minimum 4min )
③ Cooling time is total 5 min. the operating time varies,depending on the actual conditions.
2) Electric Current Time of Dry Sequence.
Dry Option
Cycle Time (min)
Heater OFF/ON
High voltage
low voltage
Cup-Borad
150
90/80
90/80
Very
200
90/80
90/80
Iron
60
90/80
90/80
Low
110
70/60
70/60
Time
30/60/120
70/60
70/60
Air Refresh
35
80/70
90/80
Tub Clean
30
70/60
70/60
Wash & Dry
40
90/80
90/80
Drying time
(150min)
end (10sec)
Cooling & Crease
(not include time)
⇨
⇨
WFW0A1*,WFW0A2*,WFC0A2*(SM).indd 23