Problem

Possible Cause

What To Do

When the sensor failure and the compressor will be running like this—if 
the potentiometer (thermostat) setting below 3 position, the compressor 
will be running 20 minutes and then stop 30 minutes, if the 
potentiometer (thermostat) setting more than 3 position, the compressor 
will be running 30 minutes and then stop 20 minutes. If find the 
compressor work like above situation, it mean the sensor failure and 
need open the back of refrigerator and change sensor of refrigerator 
evaporator 

open the cover board of air duct in freezer room, check the fan if it no 
running, then measure the voltage between the red wire and black wire 
of fan, if the voltage is 12V,the the fan motor is failure and replace it 
with a new one

disconnect power, and let the ice defrost and inspect the water if it is 
flow through the drainpipe, if could not flow out, check if it contain 
impurity and clean the drainpipe

check the fuse if it is melt or not. If the fuse is melt, it mean that the 
sensor failure or PCB failure, need change the sensor or PCB.

inspecting the CN4 defrost heater two connector.If the heater is OK then 
it must be PCB failure and change the PCB.

inspect the potentiometer (thermostat), and measure the resistance value 
by adjusting the potentiometer (thermostat), if the resistance value no 
change by adjusting the potentiometer (thermostat),

Trouble shooting guide

1

2

3

Fan no work

No defrost.Freezer room 
temperature no enough cold and 
refrigerator room OK and open 
the cover board of are duct and 
find ice formation on evaporator

the temperature of freezer and 

refrigerator are no enough cold 

and the temperature no change by 

adjusting the potentiometer 

(thermostat) 

the the fan motor is failure and replace it 
with a new one

the drainpipe contain impurity

the sensor failure or PCB failure

the defrost heater is break or PCB failure

the potentiometer failure

the sensor failure

Содержание RN-BH2536NPW

Страница 1: ...Service Manual Models RN BH2536NPW Features Energy efficiency Micro foam technology Low noise operation Thick insulation for energy efficiency Latest No 2 micro biological technology 0...

Страница 2: ...The cooling system...

Страница 3: ...The electrical diagram...

Страница 4: ...f could not flow out check if it contain impurity and clean the drainpipe check the fuse if it is melt or not If the fuse is melt it mean that the sensor failure or PCB failure need change the sensor...

Страница 5: ...e input voltage is 220V 240 but the led compressor fan defrost heater are all no work it mean the PCB failure and need change a new PCB PCB had automatic self examination open the cover of PCB at the...

Страница 6: ...Exploded view...

Страница 7: ...1 Lower door left aid closer 1 18 2106160303 Middle Drawer 2 19 3071300098 Freeze Glass partition Lower 1 20 3071300097 Freeze Glass partition Upper 1 21 2106140398 Crisper drawer 1 22 20120030157 Cov...

Страница 8: ...ocess tube 1 48 20122990683 Freeze wind parts bracket 1 49 3039900346 Water board of freeze wind parts 1 50 2400100016 Compressor 1 51 2701000085 Block gine of Wind bubble 2 52 3040300072 Fin Evaperat...

Страница 9: ...990705 Drain pan 1 71 2207700024 Drain pipe 1 72 2305700043 Cover of Control board 1 74 2500300029 Control board assembly 1 75 3040500011 Drier filter 1 76 2207500499 Upper door Middle balcony 2 77 20...

Отзывы: