background image

no problem

the time between two starting is shorter than 12min; or refrigerator room 
temperature is lower than the setting temperature, in this case, it is no 
problem. You need waiting more time.

Compressor wire not right or compressor 
damage

measure the voltage of compressor input connector, if it is OK then 
check the starting and relay of compressor, also check the wire if it is 
OK

6

product no any work

the PCB failure

check the power by multimeter,  if the input voltage is 220V-240, but the 
led, compressor, fan, defrost heater are all no work, it mean the PCB 
failure and need change a new PCB

PCB had automatic self-examination: open the cover of PCB at the back 
of product, plug in power and push the SW101 switch 3 seconds and the 
PCB begin automatic self-examination program, then the led and 
compressor and fan and defrost heater all work two second and then 
stop, all wore one time and then quit automatic self-examination 
program, and the program will return the original setting. If the 
automatic self-examination program no work, it mean the PCB failure 
and need change it

4

Compressor no starting

PCB failure

Содержание RN-BH2536NPW

Страница 1: ...Service Manual Models RN BH2536NPW Features Energy efficiency Micro foam technology Low noise operation Thick insulation for energy efficiency Latest No 2 micro biological technology 0...

Страница 2: ...The cooling system...

Страница 3: ...The electrical diagram...

Страница 4: ...f could not flow out check if it contain impurity and clean the drainpipe check the fuse if it is melt or not If the fuse is melt it mean that the sensor failure or PCB failure need change the sensor...

Страница 5: ...e input voltage is 220V 240 but the led compressor fan defrost heater are all no work it mean the PCB failure and need change a new PCB PCB had automatic self examination open the cover of PCB at the...

Страница 6: ...Exploded view...

Страница 7: ...1 Lower door left aid closer 1 18 2106160303 Middle Drawer 2 19 3071300098 Freeze Glass partition Lower 1 20 3071300097 Freeze Glass partition Upper 1 21 2106140398 Crisper drawer 1 22 20120030157 Cov...

Страница 8: ...ocess tube 1 48 20122990683 Freeze wind parts bracket 1 49 3039900346 Water board of freeze wind parts 1 50 2400100016 Compressor 1 51 2701000085 Block gine of Wind bubble 2 52 3040300072 Fin Evaperat...

Страница 9: ...990705 Drain pan 1 71 2207700024 Drain pipe 1 72 2305700043 Cover of Control board 1 74 2500300029 Control board assembly 1 75 3040500011 Drier filter 1 76 2207500499 Upper door Middle balcony 2 77 20...

Отзывы: