45
(TROUBLE 2) Digital readout display does not show programming, even if the membrane keyboard is programmed by
touching proper pads.
MEMBRANE KEYBOARD CHECK PROCEDURE
1. Check the pad termination order and nomenclature
NOTE :
Before following the particular steps listed above in the trouble shooting guide for the membrane keyboard, fail-
ure, please check for the continuity of each wire-harness between the membrane keyboard and control box
assembly.
2. Type of encoding and pad names
The membrane keyboard consists of 33 keys whose configurations are described above and provide 11 pad termintions
to be connected to the touch control circuit.