14. REPLACING THE VENTILATION MOTOR
1. Remove the microwave oven from the microwave oven location.
2. Remove 2 screws for the vent motor cover and remove it. (See cabinet removal).
3. Remove the screws for the vent motor and lift the vent motor. (See FIG. 14).
4. Unplug the wire connectors for vent motor.
5. Install the new vent motor and secure the vent motor.
6. Connect the wire connector and secure the vent motor.
7. Mount the control panel to the oven and secure it with its mounting screw.
8. Refer to Cabinet Installation and reinstall the base plate and the vent grille on the micrewave oven.
CAUTION :
Personal Injury Hazard
Because of the weight and size of the microwave oven, two people are required to safely move and install it.
Failure to do so could result in personal injury.