13
6. REPLACING THE VENT MOTOR CAPACITOR
1. Remove the vent grille from the microwave oven (See Cabinet Removal).
2. Remove the screw from the top center tab of the control panel.(See FIG. 2)
3. Remove the screw from the top center tab of wire protector.
4. Disconnect the two wire connectors from the vent motor capacitor terminals.
5. Remove the screw for vent motor capacitor and remove it, then install a new capacitor in its place.
6. Reconnect the wires to the new vent motor capacitor terminals, as shown in the FIG. 6.
7. Reinstall the control panel and the vent grille on the microwave oven.
WARNING :
Persona Injury Hazard
Disconnect from the electrical supply before servicing the unit. Failure to do so could result in electrical shock or
other personal injury.
CAUTION :
Persona Injury Hazard
Because of the weight and size of the microwave oven, two people are required to safely move and install it.
Failure to do so could result in personal injury.
FIG. 6
Содержание KOT-150S0A