19
( TROUBLE 3 ) No microwave oscillation even though fan motor rotates.
CON DITION
CHECK
RESULT
Continuity
Continuity in
backw ard
direction
or
No
Continuity
No
Continuity
0 V
Approx
15 VDC
CAUSE
Defective
high voltage
transform er
Defective
high voltage
rectifier
Defective
m agnetron
Defective
m agnetron
Defective
high voltage
transform er
Defective
high voltage
transform er
Defective
touch control
circuit
Faulty
contacts of
RELAY
(RY1) or open
relay coil
REM EDY
Replace
Replace
Replace
Replace
Replace
Replace
Replace
Replace
N o m icrowave
oscillation
C heck continuity of high
voltage rectifier in
forw ard and backw ard
direction with D C
m egge r
C heck continuity of high
voltage capacitor
term inals w ith w ires
rem oved
C onnect m egger leads to
m agne tron term inal and
m agne tron body
C heck resis tance of
prim ary and secondary
coil of high voltage
transfo rm er
C heck continuity of
m agne tron w ith w ires
rem oved
C heck continuity of
filam ent term inal of high
voltage transform er
C heck D .C. voltage
being supplied to
R ELAY (R Y1) coil
Continuity
Содержание KOR-164H0A
Страница 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION ...
Страница 25: ...24 WIRING DIAGRAM ...
Страница 27: ...26 ...
Страница 29: ...28 2 PCB CIRCUIT DIAGRAM ...