36
8. To remove fan motor assembly and guide wind.
(1) Remove screws
1
.
(2) Remove Guide wind Assy
(3) Remove Fan.
(4) Remove two screws
4
holding the fan motor
5
.
(5) Remove guide wind
2
.
(6) Reverse the above for reassembly.
9. To remove transformer.
(1) Remove four tapping screws
1
.
(2) Remove the transformer
2
.
(3) Reverse the above steps for reassembly.
CAUTION : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to
prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave
leakage. It shall not exceed 1mW/cm
2
.
Содержание KOR-145M0P
Страница 51: ...51 MP 1 MP 3 MP 2 Fig 3 Measurement Point...
Страница 54: ...54 2 PCB CIRCUIT DIAGRAM BAKED POTATO FRESH VEGETABLE SOUP KOR 145QOS Only WEIGHT MENU KOR 145MOS Only...
Страница 56: ...56 4 PRINTED CIRCUITS BOARD...
Страница 60: ...EXPLODED VIEW 60 27 26 25 24 28 29 1 2 3 4 8 7 9 10 30 11 16 15 14 17 18 19 21 22 23 6 5 34 A00 B00 32 36 31 35...