27
- Measuring should be in a counter-clockwise direction
at a rate of 1 inch/sec. If the leakage of the cabinet
door seam is unknown, move the probe more slowly.
- When measuring near a corner of the door, keep the
probe perpendicular to the areas making sure the
probe end at the base of the cone does not get closer
than 2 inches from any metal. If it does, erroneous
reading may result.
NOTE : RD : RED
WH : WHITE
BK : BLACK
GN : GREEN
BR : BROWN
OR : ORANGE
BL : BLUE
GY : GRAY
GE : GREEN/YELLOW
CL : CAVITY LAMP
FM : FAN(BLOWER) MOTOR
GM : GEARD MOTOR
[CONDITION]
DOOR : CLOSED
COOK : OFF
H.V
CAPACITOR
H.V.
TRANSFORMER
RD
RD
MAGNETRON
RELAY-A
RELAY-B
GM
CL
FM
POWER SUPPLY
~ ONLY
GN
WH
FUSE
MAGNETRON
THERMOSTAT
PRIMARY
INTERLOCK
SWITCH(UPPER)
RD
RD
RD
BK
BK
L
R
RD
CONTROL P.W.B. ASS'Y
1
2
BL
GN
D.O.M
SWITCH
WH
NC
OR
COM
NO
GY
GY
BR
WH
H.V. DIODE
BR
OR
INTERLOCK MONITOR
SWITCH (SECONDARY INTERLOCK SWITCH)
WIRING DIAGRAM
Fig. 1
Содержание KOR-145M0P
Страница 51: ...51 MP 1 MP 3 MP 2 Fig 3 Measurement Point...
Страница 54: ...54 2 PCB CIRCUIT DIAGRAM BAKED POTATO FRESH VEGETABLE SOUP KOR 145QOS Only WEIGHT MENU KOR 145MOS Only...
Страница 56: ...56 4 PRINTED CIRCUITS BOARD...
Страница 60: ...EXPLODED VIEW 60 27 26 25 24 28 29 1 2 3 4 8 7 9 10 30 11 16 15 14 17 18 19 21 22 23 6 5 34 A00 B00 32 36 31 35...