4. Method to reduce the gap between the door seal and the oven front surface.
(1) To reduce gap located on part A
Loosen a screw on stopper hinge top, and then push
the door to contact the door seal to oven front surface.
Tighten a screw.
(2) To reduce gap located on part B
Loosen two screws on stopper hinge under, and then
push the door to contact the door seal to oven front
surface.
Tighten two screws.
NOTE : A small gap may be acceptable if the microwave leakage does not exceed 4mW/cm