background image

8

MEASUREMENT OF THE MICROWAVE OUTPUT POWER

Microwave output power can be checked by indirectly measuring the temperature rise of a certain amount of water
exposed to the microwave as directed below.

Procedure

1. Microwave power output measurement is made with the microwave oven supplied at rated voltage and operated

at its maximum microwave power setting with a load of 1,000±5cc of potable water.

2. The water is contained in a cylindrical borosilicate glass vessel having a maximum material thickness of 3 mm

and an outside diameter of approximately 190 mm.

3. The oven and the empty vessel are at ambient temperature prior to the start of the test.

The initial temperature of the water is 10±2˚C(50±3.6˚F).
It is measured immediately before the water is added to the vessel. After addition of the water to the vessel, the
load is immediately placed on the center of the shelf which is in the lowest normal position.

4. Microwave power is switched on.

5. Heating time should be exactly 52 seconds.

Heating time is measured while the microwave generator is
operating at full power.
The filament heat-up time for magnetrons is not included.

6. The initial and final water temperatures are selected so that

the maximum defference between the ambient and final
water temperature is 5K.

7. The microwave power output P in watts is calculated from the following formula:

• 

T is actual temperature rise.

• t is the heating time.
The power measured should be 800W±10%.

CAUTION  :

1. Water load should be measured exactly to 1 liters.
2. Input power voltage should be exactly 230 volts as specified.
3. Ambient temperature should be 20±2˚C (68±3.6˚F)

Water Load

  Tray  

P = 4187 X

T/t

Содержание KOG-3605

Страница 1: ...Service Manual Microwave Oven Model KOG 3605 DAEWOO ELECTRONICS CO LTD...

Страница 2: ...avity for proper alignment integrity and connection d Any defective or misadjusted components in the interlock monitor door seal and microwave generation and transmission systems shall be repaired rep...

Страница 3: ...make repairs 1 A broken door hinge 2 A broken door viewing screen 3 A broken front panel oven cavity 4 A loosened door lock 5 A broken door lock The door seal area and oven cavity surface be kept clea...

Страница 4: ...50 W COMBINATION 2200 W MICROWAVE ENERGY OUTPUT 800 W MICROWAVE FREQUENCY 2450 MHz OUTSIDE DIMENSIONS WXHXD 465X360X274 mm CAVITY DIMENSIONS WXHXD 290X290X220mm NET WEIGHT 14 5 Kg TIMER 35 min DUAL SP...

Страница 5: ...e of special heat resistant glass Food in a proper receptacle is placed on this tray for cooking Roller Guide This must always be used for cooking together with the glass cooking tray Coupler this fit...

Страница 6: ...bout 1 0 meters long Do not use an extension cord If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard...

Страница 7: ...set at any time during the cooking cycle by only turning the timer knob Do not let the timer continue to operate after removing food 7 NOTE When using the GRILL KOG 368 9 OS mode Do not open the door...

Страница 8: ...immediately before the water is added to the vessel After addition of the water to the vessel the load is immediately placed on the center of the shelf which is in the lowest normal position 4 Microw...

Страница 9: ...Place it at the center of the tray and set it in a cavity D Close the door and operate the oven E Measure the leakage by using microwave energy survery meter with dual ranges set to 2450 MHz Measured...

Страница 10: ...10 WIRING DIAGRAM SLOW ACTING RELAY...

Страница 11: ...11 WIRING DIAGRAM...

Страница 12: ...tae transformer and this secondary voltage is increased by the action of the diode and the charging of the high voltage capacitor This resultant D C voltage is then applied to the anode of the magnetr...

Страница 13: ...o the high voltage transformer to stop microwave oscillation Fan motor timer motor and turntable motor stop rotating Oven lamp turn off As soon as the door is opened monitor switch close NC to create...

Страница 14: ...epair work 2 Warning about the electric charge in the high voltage capacitor For about 30 seconds after the operation stopped and electric charge remains in the high voltage capacitor When replacing o...

Страница 15: ...nge top 2 Remove the stopper hinge top and door assembly from top plate of cavity 3 Remove the stopper hinge top from door assembly 4 Reverse the above for reassembly taking care to replace fixing glu...

Страница 16: ...three screws on bottom hinge and then the door to contact the door seal to oven front surface 2 Tighten three screws 3 To reduce gap locatated on part C See Fig A 1 Loosen a screw on the interlock sw...

Страница 17: ...timer assembly 5 Pull out the timer knob from the timer assembly 6 Pull out the timer coupler from the timer assembly 7 Remove the screw pull out the switch micro 8 Remove the screw which secure the V...

Страница 18: ...pacitor holder 2 Remove the H V diode from the capacitor holder 3 Reverse the above steps for reassembly High voltage circuit wiring 7 To remove magnetron 1 Remove three screws which secure the magnet...

Страница 19: ...nsformer 2 Remove the transformer 3 Reverse the above steps for reassembly CAUTION Never install the magnetron without the metallic gasket plate which is packed with each magnetron to prevent microwav...

Страница 20: ...2 3 4 5 6 7 3513301100 3512801700 7002500613 7392500008 7002400413 3515000700 7S627W50X1 1 1 1 1 2 2 2 SPP T0 8 230V 1000W TRS 5X6 MFCR 6N 2 5 SUS TRS 4X4 MFCR C3771BD FLG NUT M5X0 8P MFZN INSULATOR H...

Страница 21: ...d the hook locks the oven door If the door is not closed properly the oven will not operate When the door is closed the hook pushes the button of the micro switch Then the button of the primary interl...

Страница 22: ...he two mounting screws b Adjust interlock switch assembly position c Confirm the gap 1 2mm described above d Make sure that push lever moves smoothly after adjustments is completed e Completely tighte...

Страница 23: ...nterlock switch secondary interlock switch and interlock monitor switch All these switches must be replace at the same time Replace H V T Thermal cut out Outlet has Proper voltage Check continuity of...

Страница 24: ...he contacts of a relay operate oven Normal reading should be approx 0 Meter with 6V or higher voltage batteries should be used to check the normal direction resistance of the diode NO GOOD Poor contin...

Страница 25: ...readings should be as follows Secondary winding Approx 120 10 Filament winding Approx 0 Primary winding Approx 0 2 High voltage capacitor A Check continuity of capacitor with meter on the highest OHM...

Страница 26: ...e ohmmeter Fig a Condition 1 Door is opened 2 Common terminal of the monitor switch disconnected 3 In case of secondary interlock switch Lamp on or zero resistance ohmmeter Fig c Condition 1 Door is c...

Страница 27: ...0 1 KOG 3605 BARRIER SCREEN O PMMA T1 5 A1 3512202500 1 KOG 3605 A2 FRAME DOOR ABS A3 3515201500 STOPPER HINGE T AS KOR 61150S 1 A4 3511705500 DOOR WELD AS KOR 61150S 1 A5 3517002800 BARRIER SCREEN PO...

Страница 28: ...11 SCREW TAPPING T2S PAN 3X15 MFZN 1 B8 4415A17352 SW MICRO VP 533A OF 1 B9 7121301511 SCREW TAPPING T2S PAN 3X15 MFZN 1 B10 3517400500 COUPLER VPC KNOB POM 1 B11 7122401211 SCREW TAPPING T2S TRS 4X12...

Страница 29: ...29 3 Main Unit...

Страница 30: ...F22 SCREW TAPPING 7S312X40A1 T1 TRS 4X10 SE MFZN 2 F23 SCREW MATCHINE 7601400811 PAN 4X8 PW MFZN 2 F24 COVER B 3511402500 SBHG T0 8 1 F25 MOTOR SHADED POLE 3963512100 MW10CA R01 1 F26 FAN 3511800300...

Отзывы: