38
7. Case of no stopping of the count down timer
When the door is opened during operation, the count down timer does not stop.
- Check method
POINT
STATE
DOOR OPEN
DOOR CLOSED
A
OPEN
CLOSE
B
+5V DC
GND
B
A
CHECK NO
METHOD
REMEDY
1
Check the stage(ON,OFF) of the door open
Replace door open monitor swith.
monitor switch by resistance measurement.
Содержание KOC-1B4K0S
Страница 30: ...29 10 WIRING DIAGRAM KOC 1B4K0S 1B4K0S10 1B4K0S 20 1B4K5S 1B4K5S10...
Страница 31: ...30 KOC 1B4K0S01 1B4K0S31 1B4K9SA1...
Страница 40: ...39 13 P C B CIRCUIT DIAGRAM...