• Do not allow multiple devices to be connected at the same time.
• Run the generator for 3 minutes without connecting the load.
• Various devices need more power when starting.
• Connect the devices one after the other according to the maximum power allowed by your
generator.
• Before connecting, make sure that all devices are in good working order.
• If the connected device no longer works or stops suddenly, disconnect the load immediately
using the emergency switch, turn off the device and test it.
• Remember to turn off all devices before stopping the generator.
• If the display (voltmeter) shows a voltage value of 230V ±10% (50Hz), you can use the generator.
• If the voltage value on the display (voltmeter) goes beyond 230V ±10% (50Hz), it is necessary to
stop the generator
• DC 12V cannot be used simultaneously with 230V.
• The generator must be connected to the mains by a qualified person.
• Incorrect connection may cause serious damage.
Fill in the fuel
tank with
gasoline
Turn the ignition
key to start
the engine (for
electric start
models)
Check oil level
Put the choke
to the „OPEN’’
(RUN)
Open the fuel
cock
Connect
the power
consumer(s) to
the generator
Put the ignition
switch to „ON’’
Put the choke
to the „CLOSE’’
(CHOKE) position
Gently pull the
starter handle to
start the engine
ENGINE STOP
• Turn off the power to devices connected to the generator.
• Pull starting: Put the ignition switch to
OFF
.
• Electric starting: Turn the key
OFF
.
• Close the fuel cock.
GENERATOR EMERGENCY SWITCH
DAEWOO
generators are equipped with an emergency switch
(fig. 2). When the generator is running
with the load connected, the emergency switch must be in the
ON
position.
In the event of an overload protection trip, the emergency switch will automatically move to the
OFF
position and stop the generator. This means that the power plant is overloaded or the consumer is faulty.
Switch off the generator immediately, check the serviceability of the consumers and the generator.
Stopping the generator with connected power consumers can damage the generator.
IMPORTANT!
Содержание GDA 3500
Страница 75: ...71 DAEWOO POWER COM 1 15 40 95 1000 3 1 3 min...
Страница 77: ...73 DAEWOO POWER COM 3 230V 10 50 Hz 230V 10 50 Hz 12 230 DAEWOO 2 16 DAEWOO 16 11 2 16 ATS DAEWOO DAEWOO UWAGA...
Страница 79: ...75 DAEWOO POWER COM DF 3 4 1 1 2 4 2 GDA 7500DFE GDA 3500DFE 5 OFF 10 5 6 6 1...
Страница 81: ...77 DAEWOO POWER COM 10 50 11 F6RTC NGK BPR6ES 0 7 0 8 5 10...
Страница 83: ...79 DAEWOO POWER COM ON...
Страница 84: ...80 UA GDA 3500 3500E 3500DFE 6500 6500E 7500E 7500E 3 GDA 7500DPE 3 7500DFE 8500E 8500E 3 9500DPE 3 2012 19 EC...
Страница 169: ......
Страница 170: ...Manufactured under license of DAEWOO International Corporation Korea WWW DAEWOO POWER COM 1...