9
DAEWOO-POWER.COM
GENERATOR
POWER
POWER
ATS
GENERATOR
ATS
EMERGENCY SWITCH OF 16A SOCKET
DAEWOO
generators with 16A sockets are equipped with an emergency socket switch
11
(fig. 2).
When the generator is running with a load connected to this outlet, the emergency switch must be in
the
ON
position.
In the event of a short circuit protection trip, the emergency switch will automatically switch to the
OFF
position and stop the load on this outlet. This means that the power plant is overloaded or the
consumer connected to this outlet is faulty. At the same time, consumers connected to other outlets
will continue to work and the generator will not turn off.
Immediately disconnect the consumer from the 16A socket and check its serviceability.
USING THE GENERATOR IN ATS MODE
The
DAEWOO
automation unit is an automatic power plant control system for organizing backup power
supply to consumers of electrical energy when the main power source is off. The automation unit is
designed to work together with
DAEWOO
power plants that have the option of automatic operation and
a connector for connecting the unit placed on the front panel.
Power plants that do not have this option cannot be used to work with an automation unit.
Structurally, the automation unit is made in a metal case with a possible wall mounting. The connection
to the power plant is made using a special control cable (included) and a power wire. The connection
of the power output of the power plant, the power input of the electrical network and the reserved
consumers of electrical energy is carried out using screw terminals located inside the unit.
ATS OPERATION IN AUTO MODE
1. Connect the automation unit to the power plant and the main power supply network.
2. Connect the line of redundant consumers.
3. Move the mode switch to the «
automatic
» position.
4. If there is voltage from the main power source, the system goes into standby mode, the power supply
of the redundant consumers comes from the main power source.
5. In case of voltage drop at the main power source, the system starts the engine of the power plant
according to the above algorithm and switches the power supply of the redundant consumers to the
power plant.
FEATURES OF GAS GENERATOR OPERATION (FIG. 6)
DAEWOO
Dual Fuel generators are universal 2-fuel generators capable of running on fuel gas and
gasoline.
DAEWOO
gas generators are equipped with all the necessary equipment to connect to a gas cylinder
and start operation:
Reducer-stabilizer on gas supply.
A hose with a connector for gas cylinder.
The operation of the generator on gas is allowed only on liquefied cylinder-stored gas. It is
forbidden to connect the generator to the main gas pipeline.
ATTENTION!
Single-phase connection
Three-phase connection
When operating the generator on liquefied gas, make sure there are no open flames or sparks nearby.
Содержание GDA 3500
Страница 75: ...71 DAEWOO POWER COM 1 15 40 95 1000 3 1 3 min...
Страница 77: ...73 DAEWOO POWER COM 3 230V 10 50 Hz 230V 10 50 Hz 12 230 DAEWOO 2 16 DAEWOO 16 11 2 16 ATS DAEWOO DAEWOO UWAGA...
Страница 79: ...75 DAEWOO POWER COM DF 3 4 1 1 2 4 2 GDA 7500DFE GDA 3500DFE 5 OFF 10 5 6 6 1...
Страница 81: ...77 DAEWOO POWER COM 10 50 11 F6RTC NGK BPR6ES 0 7 0 8 5 10...
Страница 83: ...79 DAEWOO POWER COM ON...
Страница 84: ...80 UA GDA 3500 3500E 3500DFE 6500 6500E 7500E 7500E 3 GDA 7500DPE 3 7500DFE 8500E 8500E 3 9500DPE 3 2012 19 EC...
Страница 169: ......
Страница 170: ...Manufactured under license of DAEWOO International Corporation Korea WWW DAEWOO POWER COM 1...