5. Control way of Errors (if any)
1) “F-sensor” error
Cause : F-sensor open or short
Control : Condition of ambient temperature
How to reset : If F-sensor is normal, the error is terminal temperature.
CONTENTS
REMARKS
2) “R-sensor” error
Cause : R-sensor open or short
Control : Condition of ambient temperature
How to reset : If R-sensor is normal, the error is terminal temperature.
3) “RT-sensor” error
Cause : RT-sensor open or short (full down)
Control : Normal operation, deletion of control by RT-sensor
If RT-sensor is normal, the error is terminated automatically.
4) “D-sensor” error
Cause : D-sensor open or short (full down)
Control : Time limit (30 min) of defrosting return
If D-sensor is normal, the error is terminated automatically.
5) “Door” error
Cause : in case it senses that door is open for more than 1 hour.
Control : Deletion of function related door switch sensing
If door switch (open & close) is sensed, the error is terminated automatically.
6) “Cycle” error
Cause : in case comp. works for over 3 hours when D-sensor temp. is over -5
℃
Control : normal operation
When D-sensor temp. is below -5
℃
in comp. off it is terminated.
7) “Return after defrosting” error
Cause : in case defrosting return is done by time limit of 80 min
Control : Deletion of Pre-cool mode in defrosting mode
If defrosting return is done by D-sensor, it is terminated.
8) A/S forced defrosting mode
Push “REFRIGERATOR SET” button 5 times while pushing “FREEZER SET” button
Simultaneously.
Control : A/S forced defrosting control (Pre-cool is deleted)
If D-sensor temp. is over 10
℃
, the mode is terminated automatically.
When all error code is normal, the Refrigerator reset
35 / 20
35 / 20
26 / 22
27 / 45
16 / 41
14 / 50
ON/OFF (min)
Over 41
℃
~ 41
℃
~ 31
℃
~ 21
℃
~ 15
℃
~ 9
℃
RT-S
6 / 4
4 / 6
3 / 7
2 / 10
3 / 50
OFF
ON/OFF (min)
Over 41
℃
~ 41
℃
~ 31
℃
~ 21
℃
~ 15
℃
~ 9
℃
RT-S
Содержание FRS(N)-U20IA
Страница 4: ...3 2 EXTERNAL VIEWS 2 1 External Size FRS N U20IA...
Страница 5: ...4 FRS N U20DA FRS N U20EA...
Страница 6: ...5 FRS N U20FA FRS N U20GA...
Страница 41: ...40 6 1 Wiring Diagram 6 DIAGRAM FRS N U20IA...
Страница 42: ...41 FRS N U20DA EA FA GA...
Страница 43: ...42 6 2 Circuit Diagram of Main PCB FRS N U20IA...
Страница 44: ...43...
Страница 45: ...44 FRS N U20DA EA FA GA...
Страница 46: ...45...
Страница 88: ...87 11 5 Dispenser Water Flow...
Страница 89: ...88 CABINET 12 1 FRS N U20IA 12 EXPLODED VIEW PARTS LIST...
Страница 90: ...89 MECH ROOM...
Страница 91: ...90 R ROOM...
Страница 92: ...91 F ROOM...
Страница 93: ...92 F DOOR...
Страница 94: ...93 R DOOR...
Страница 99: ...98 CABINET 12 2 FRS N U20DA...
Страница 100: ...99 MECH ROOM...
Страница 101: ...100 R ROOM...
Страница 102: ...101 F ROOM...
Страница 103: ...102 F DOOR...
Страница 104: ...103 R DOOR...
Страница 110: ...109 CABINET 12 3 FRS N U20EA...
Страница 111: ...110 MECH ROOM...
Страница 112: ...111 R ROOM...
Страница 113: ...112 F ROOM...
Страница 114: ...113 F DOOR...
Страница 115: ...114 R DOOR...
Страница 121: ...120 CABINET 12 4 FRS N U20FA...
Страница 122: ...121 MECH ROOM...
Страница 123: ...122 R ROOM...
Страница 124: ...123 F ROOM...
Страница 125: ...124 F DOOR...
Страница 126: ...125 R DOOR...
Страница 132: ...131 CABINET 12 5 FRS N U20GA...
Страница 133: ...132 MECH ROOM...
Страница 134: ...133 R ROOM...
Страница 135: ...134 F ROOM...
Страница 136: ...135 F DOOR...
Страница 137: ...136 R DOOR...
Страница 143: ...686 AHYE ON DONG MAPO GU S E OUL KOR E A C P O BOX 8003 S E OUL KOR E A PRINTED DATE JULY 2005 DAEWOO ELECTRONICS CORP...