9
FEATURE
Contact of safety switch
Contact lever A
Normal (ON)
Position of
unbalanced load (OFF)
Automatic Unbalance Adjustment
Circulating-Water Course and Lint Filter
The alarm finished when you close the lid after opening
it. Check the unbalance of the wash load and the
installation condition.
NOTES
Filter
Tub
Outer tub
Water
channel
Pulsator
This system is to prevent abnormal vibration during intermittent spin and spin process.
CIRCULATING-WATER
The washing and rinsing effects have been
improved by adopting the water system in
which water in the tub is circulated in a
designed pattern.
When the pulsator rotates during the washing
or rinsing process, the water below the
pulsator fans creates a water currents as
shown in figure.
The water is then discharged from the upper
part of the tub through the water channel.
About 40 L/min. water is circulated at the ‘high’
water level, standard wash load and standard
water currents.
FUNCTIONAL PRINCIPLE
1. When the lid is closed, the micro switch
contact is "ON' position.
2. In case that wash loads get uneven during
spin, the outer tub hits the safety switch due
to the serious vibration, and the spin
process is interrupted.
3. In case that P.C.B. ASS’Y gets “OFF” signal
from the safety switch, spin process is
stopped and rinse process is started
automatically.
4. If the safety switch is operated due to the
unbalance of the tub, the program is
stopped and the alarm is given.
Contact of micro switch
Lid closing
('ON' position)
Lid closing
('OFF' position)
Содержание DWF-204AY
Страница 29: ...APPENDIX 28 PCB ASS Y Wiring Diagram...
Страница 31: ...30 PARTS DIAGRAM B12 B13...
Страница 32: ...31 PARTS DIAGRAM C13 C14 C15 C01 C02 C03 C04 C05 C07 C06 C09 C10 C11 C12 C08 C13 C14 C15...
Страница 33: ...32 PARTS DIAGRAM D01 D02 D03 D05 D08 D09 D07 D10 D11 D12 D13 D16 D17 D15 D14 D04...